Worked example
Dual-Fuel Heat Pump Crossover Against Natural Gas
A homeowner compares a dual-fuel heat pump with a 90% gas furnace. The electric rate is $0.16/kWh, gas is $1.30/therm, and the heat pump reaches COP 4.1, 2.7 and 1.8 at the three entered temperatures.
Try it Change the price of natural gas by 30 cents per therm. Read the new crossover COP and check whether the graph crosses the gas line.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Heat pump bill savings / year
- USD
- Break-even COP vs. natural gas
- CO₂ reduction / year
- kg CO₂
The modeled heat pump costs more per year than the selected baseline fuel.
Heating cost crossover
- Load-weighted seasonal COP
- Heat pump electricity (kWh/year)
- Heat pump bill / year
- USD
- Heat pump CO₂ / year
- kg CO₂
- Heat pump cost at 5 °F
- $/MMBtu
- Heat pump cost at 17 °F
- $/MMBtu
- Heat pump cost at 47 °F
- $/MMBtu
Fossil fuel comparison
Natural gas Baseline
- Delivered heat price
- 14.44 $/MMBtu
- Break-even COP
- 3.25
- Crossover temperature
- 28.7 °F
- Bill / year
- 751.11 USD
- CO₂ / year
- 3,066 kg CO₂
Propane
- Delivered heat price
- 32.8 $/MMBtu
- Break-even COP
- 1.43
- Crossover temperature
- Outside chart range
- Bill / year
- 1,705.81 USD
- CO₂ / year
- 3,632 kg CO₂
Heating oil
- Delivered heat price
- 30.58 $/MMBtu
- Break-even COP
- 1.53
- Crossover temperature
- Outside chart range
- Bill / year
- 1,590.15 USD
- CO₂ / year
- 4,525 kg CO₂
Inputs used
- Electricity rate
- 0.16 $/kWh
- Natural gas rate
- 1.3 $/therm
- Propane rate
- 2.7 $/US gal
- Heating oil rate
- 3.6 $/US gal
- Gas appliance AFUE
- 90 %
- Propane appliance AFUE
- 90 %
- Oil appliance AFUE
- 85 %
- COP at 47°F
- 4.1
- COP at 17°F
- 2.7
- COP at 5°F
- 1.8
- Baseline fuel
- Natural gas
- Annual delivered heat
- 52 MMBtu
- Share of heat at 47°F
- 55 %
- Share of heat at 17°F
- 35 %
- Share of heat at 5°F
- 10 %
- Electric grid CO₂ intensity
- 0.38 kg CO₂/kWh
How this calculation works
Heat pump cost per delivered MMBtu equals 293.071 × electricity price ÷ COP. Fuel cost per delivered MMBtu is the retail price divided by fuel heat content and AFUE. The crossover COP is the electricity-price numerator divided by the fuel’s delivered heat price.
The seasonal COP is the delivered-heat-weighted harmonic mean of the three entered COPs. Bin percentages describe heat output, so a colder bin can represent a larger share of heating than of hours.
Fuel heat content uses 0.100 MMBtu per therm, 0.091452 MMBtu per US gallon of propane and 0.1385 MMBtu per US gallon of heating oil. Direct combustion emits 53.06, 62.87 and 73.96 kg CO₂ per MMBtu of fuel input, respectively. Heat pump emissions use the entered electricity factor.
The crossover is economic. Check temperature-specific capacity, defrost, backup heat, utility fixed charges, equipment and distribution losses separately.
References
Frequently asked questions
What does an electric-gas crossover around COP 3 mean here?
The heat pump needs about that COP for the same marginal cost per unit of useful heat. The exact threshold follows the entered gas AFUE and prices.
Does my monthly gas service fee belong in the dual-fuel crossover rate?
For selecting a heat source while both services remain connected, use marginal rates. Consider a removable fixed charge separately when evaluating a full gas disconnection.