Dual-Fuel Heat Pump Crossover Against Natural Gas

A homeowner compares a dual-fuel heat pump with a 90% gas furnace. The electric rate is $0.16/kWh, gas is $1.30/therm, and the heat pump reaches COP 4.1, 2.7 and 1.8 at the three entered temperatures.

Try it Change the price of natural gas by 30 cents per therm. Read the new crossover COP and check whether the graph crosses the gas line.

Utility rates and efficiency
$/kWh
$/therm
$/US gal
$/US gal
%
%
%
Heat pump performance
Annual comparison
MMBtu
%

The three shares represent delivered heat and must add up to 100%.

%
%
kg CO₂/kWh

Example assumption. Enter your local electricity emissions factor.

Heat pump bill savings / year
-27.53 USD
Break-even COP vs. natural gas
3.25
CO₂ reduction / year
1,216 kg CO₂

The modeled heat pump costs more per year than the selected baseline fuel.

Heating cost crossover

Delivered heating cost by outdoor temperatureThe three heat pump costs are 26.05 $/MMBtu, 17.37 $/MMBtu, 11.44 $/MMBtu at the cold-to-warm anchors. Baseline: 28.7 °F. $/MMBtu0102030405 °F17 °F47 °FNatural gasPropaneHeating oilHeat pump
The heat pump curve uses linearly interpolated COP between the three anchors. Horizontal lines show each fossil fuel’s cost after AFUE.
Load-weighted seasonal COP
3.13
Heat pump electricity (kWh/year)
4,867
Heat pump bill / year
778.64 USD
Heat pump CO₂ / year
1,849 kg CO₂
Heat pump cost at 5 °F
26.05 $/MMBtu
Heat pump cost at 17 °F
17.37 $/MMBtu
Heat pump cost at 47 °F
11.44 $/MMBtu

Fossil fuel comparison

Natural gas Baseline

Delivered heat price
14.44 $/MMBtu
Break-even COP
3.25
Crossover temperature
28.7 °F
Bill / year
751.11 USD
CO₂ / year
3,066 kg CO₂

Propane

Delivered heat price
32.8 $/MMBtu
Break-even COP
1.43
Crossover temperature
Outside chart range
Bill / year
1,705.81 USD
CO₂ / year
3,632 kg CO₂

Heating oil

Delivered heat price
30.58 $/MMBtu
Break-even COP
1.53
Crossover temperature
Outside chart range
Bill / year
1,590.15 USD
CO₂ / year
4,525 kg CO₂
Download

How this calculation works

Heat pump cost per delivered MMBtu equals 293.071 × electricity price ÷ COP. Fuel cost per delivered MMBtu is the retail price divided by fuel heat content and AFUE. The crossover COP is the electricity-price numerator divided by the fuel’s delivered heat price.

The seasonal COP is the delivered-heat-weighted harmonic mean of the three entered COPs. Bin percentages describe heat output, so a colder bin can represent a larger share of heating than of hours.

Fuel heat content uses 0.100 MMBtu per therm, 0.091452 MMBtu per US gallon of propane and 0.1385 MMBtu per US gallon of heating oil. Direct combustion emits 53.06, 62.87 and 73.96 kg CO₂ per MMBtu of fuel input, respectively. Heat pump emissions use the entered electricity factor.

The crossover is economic. Check temperature-specific capacity, defrost, backup heat, utility fixed charges, equipment and distribution losses separately.

References

Frequently asked questions

What does an electric-gas crossover around COP 3 mean here?

The heat pump needs about that COP for the same marginal cost per unit of useful heat. The exact threshold follows the entered gas AFUE and prices.

Does my monthly gas service fee belong in the dual-fuel crossover rate?

For selecting a heat source while both services remain connected, use marginal rates. Consider a removable fixed charge separately when evaluating a full gas disconnection.