Worked example
Oil Boiler vs. a Heat Pump During the Shoulder Season
An oil boiler burns $4.155/gal fuel at 80% AFUE. The owner is considering a heat pump that handles much of the winter and is evaluating 46 MMBtu of yearly delivered heat.
Try it Change the oil rate to a lower delivered quote. Observe the crossover temperatures and the annual bill change against oil.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Heat pump bill savings / year
- USD
- Break-even COP vs. heating oil
- CO₂ reduction / year
- kg CO₂
Positive savings show that the modeled heat pump costs less than the baseline fuel.
Heating cost crossover
- Load-weighted seasonal COP
- Heat pump electricity (kWh/year)
- Heat pump bill / year
- USD
- Heat pump CO₂ / year
- kg CO₂
- Heat pump cost at 5 °F
- $/MMBtu
- Heat pump cost at 17 °F
- $/MMBtu
- Heat pump cost at 47 °F
- $/MMBtu
Fossil fuel comparison
Natural gas
- Delivered heat price
- 15.76 $/MMBtu
- Break-even COP
- 4.65
- Crossover temperature
- Outside chart range
- Bill / year
- 725 USD
- CO₂ / year
- 2,653 kg CO₂
Propane
- Delivered heat price
- 32.8 $/MMBtu
- Break-even COP
- 2.23
- Crossover temperature
- 12.1 °F
- Bill / year
- 1,508.99 USD
- CO₂ / year
- 3,213 kg CO₂
Heating oil Baseline
- Delivered heat price
- 37.5 $/MMBtu
- Break-even COP
- 1.95
- Crossover temperature
- 8.4 °F
- Bill / year
- 1,725 USD
- CO₂ / year
- 4,253 kg CO₂
Inputs used
- Electricity rate
- 0.25 $/kWh
- Natural gas rate
- 1.45 $/therm
- Propane rate
- 2.7 $/US gal
- Heating oil rate
- 4.155 $/US gal
- Gas appliance AFUE
- 92 %
- Propane appliance AFUE
- 90 %
- Oil appliance AFUE
- 80 %
- COP at 47°F
- 3.9
- COP at 17°F
- 2.6
- COP at 5°F
- 1.7
- Baseline fuel
- Heating oil
- Annual delivered heat
- 46 MMBtu
- Share of heat at 47°F
- 55 %
- Share of heat at 17°F
- 35 %
- Share of heat at 5°F
- 10 %
- Electric grid CO₂ intensity
- 0.38 kg CO₂/kWh
How this calculation works
Heat pump cost per delivered MMBtu equals 293.071 × electricity price ÷ COP. Fuel cost per delivered MMBtu is the retail price divided by fuel heat content and AFUE. The crossover COP is the electricity-price numerator divided by the fuel’s delivered heat price.
The seasonal COP is the delivered-heat-weighted harmonic mean of the three entered COPs. Bin percentages describe heat output, so a colder bin can represent a larger share of heating than of hours.
Fuel heat content uses 0.100 MMBtu per therm, 0.091452 MMBtu per US gallon of propane and 0.1385 MMBtu per US gallon of heating oil. Direct combustion emits 53.06, 62.87 and 73.96 kg CO₂ per MMBtu of fuel input, respectively. Heat pump emissions use the entered electricity factor.
The crossover is economic. Check temperature-specific capacity, defrost, backup heat, utility fixed charges, equipment and distribution losses separately.
References
Frequently asked questions
Why normalize the oil quote to useful heat for the shoulder-season case?
A gallon price covers the fuel input, and only a fraction reaches the conditioned space. Normalizing by fuel heat content and AFUE gives a comparable delivered-heat price.
How can I model an oil boiler that serves domestic hot water too?
Estimate and remove the domestic hot-water portion before entering the space-heating load. Evaluate water heating separately.