Worked example
A 25 MMBtu Mild-Season Heat Pump Estimate
A coastal bungalow has a light 25 MMBtu heating year. Nearly all heating is approximated by the mildest bin, with a representative COP of 4.2 at 47°F.
Try it Move 20 points of the heat share from 47°F to 17°F. Leave the three COP values unchanged and compare seasonal efficiency.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Heat pump bill savings / year
- USD
- Break-even COP vs. natural gas
- CO₂ reduction / year
- kg CO₂
Positive savings show that the modeled heat pump costs less than the baseline fuel.
Heating cost crossover
- Load-weighted seasonal COP
- Heat pump electricity (kWh/year)
- Heat pump bill / year
- USD
- Heat pump CO₂ / year
- kg CO₂
- Heat pump cost at 5 °F
- $/MMBtu
- Heat pump cost at 17 °F
- $/MMBtu
- Heat pump cost at 47 °F
- $/MMBtu
Fossil fuel comparison
Natural gas Baseline
- Delivered heat price
- 15.76 $/MMBtu
- Break-even COP
- 4.09
- Crossover temperature
- 45.1 °F
- Bill / year
- 394.02 USD
- CO₂ / year
- 1,442 kg CO₂
Propane
- Delivered heat price
- 32.8 $/MMBtu
- Break-even COP
- 1.97
- Crossover temperature
- 9.9 °F
- Bill / year
- 820.1 USD
- CO₂ / year
- 1,746 kg CO₂
Heating oil
- Delivered heat price
- 30.58 $/MMBtu
- Break-even COP
- 2.11
- Crossover temperature
- 11.8 °F
- Bill / year
- 764.49 USD
- CO₂ / year
- 2,175 kg CO₂
Inputs used
- Electricity rate
- 0.22 $/kWh
- Natural gas rate
- 1.45 $/therm
- Propane rate
- 2.7 $/US gal
- Heating oil rate
- 3.6 $/US gal
- Gas appliance AFUE
- 92 %
- Propane appliance AFUE
- 90 %
- Oil appliance AFUE
- 85 %
- COP at 47°F
- 4.2
- COP at 17°F
- 2.5
- COP at 5°F
- 1.6
- Baseline fuel
- Natural gas
- Annual delivered heat
- 25 MMBtu
- Share of heat at 47°F
- 100 %
- Share of heat at 17°F
- 0 %
- Share of heat at 5°F
- 0 %
- Electric grid CO₂ intensity
- 0.38 kg CO₂/kWh
How this calculation works
Heat pump cost per delivered MMBtu equals 293.071 × electricity price ÷ COP. Fuel cost per delivered MMBtu is the retail price divided by fuel heat content and AFUE. The crossover COP is the electricity-price numerator divided by the fuel’s delivered heat price.
The seasonal COP is the delivered-heat-weighted harmonic mean of the three entered COPs. Bin percentages describe heat output, so a colder bin can represent a larger share of heating than of hours.
Fuel heat content uses 0.100 MMBtu per therm, 0.091452 MMBtu per US gallon of propane and 0.1385 MMBtu per US gallon of heating oil. Direct combustion emits 53.06, 62.87 and 73.96 kg CO₂ per MMBtu of fuel input, respectively. Heat pump emissions use the entered electricity factor.
The crossover is economic. Check temperature-specific capacity, defrost, backup heat, utility fixed charges, equipment and distribution losses separately.
References
Frequently asked questions
Why does the mild-season COP equal the 47°F entry in this example?
All annual delivered heat is assigned to that one anchor. There are no other bin values to contribute to the seasonal average.
How do I add a few unusual cold days to this bungalow calculation?
Estimate their share of delivered heat and shift that percentage from the 47°F bin into the appropriate colder bin. Keep the shares totaled at 100%.