WaterTreatLab

Biological treatment / Worked example

Extended Aeration with Low F/M

Calculate F/M of about 0.042 d⁻¹, solids age and carbon-only oxygen demand for a 1.2 MGD extended aeration train.

Inputs

Aeration & food
MGD
mg/L
gal
mg/L
mg/L
mL/L
Solids leaving system
gpm
mg/L
mg/L
lb
E.g. secondary blanket
Oxygen demand
mg/L

Results

US customary
F/M ratio
0.041905 d⁻¹
MCRT / sludge age
26.017 d
Sludge volume index
100 mL/g
Actual oxygen demand
1,225 lb O₂/d 555.64 kg O₂/d
Aeration & solids returnLive diagram
Aeration & solids returnSolids inventory and wasting boundary. Return activated sludge remains in the system. Aeration tank4,200 mg/L MLSSSecondary clarifier100 mL/g SVIReturn sludge (RAS)Waste (WAS)26.017 d MCRT
Solids inventory and wasting boundary. Return activated sludge remains in the system.
Carbonaceous oxygen
1,225 lb O₂/d
Nitrification oxygen
0 lb O₂/d
Influent BOD₅ load
1,100.9 lb/d
Total solids inventory
35,028 lb
Wasted solids
1,297 lb/d
Effluent solids
49.319 lb/d

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Food load per MLVSS inventory is 1.2 × 110 ÷ (1.0 × 3,150) ≈ 0.0419 d⁻¹.
  2. With a low daily waste flow the modeled MCRT is about 26.02 days. Carbon-only oxygen demand is about 1,225 lb/day.

More worked examples

Equations & conventions

Food-to-microorganism ratio
F/M = (Q × BOD₅) / (V × MLVSS)

Use influent load to the aeration stage and the volatile mixed-liquor inventory. With consistent volume and concentration units the result is per day.

Solids retention time
MCRT = (V × MLSS + extra mass) / (QWAS × XWAS + Qeff × TSSₑ)

The calculator estimates effluent flow as influent minus WAS. Include measured clarifier solids in extra inventory if using the whole-train basis. RAS stays within the inventory boundary.

Sludge volume index
SVI = 1,000 × SV₃₀ / MLSS

Use 30-minute settled volume in mL/L and MLSS in mg/L. Compare time trends at the same test conditions.

Actual oxygen requirement
AOR = f꜀ × load(BOD₅ removed) + 4.57 × load(N oxidized)

The second term is optional. Use the fraction of incoming TKN expected to oxidize to nitrate. The carbon factor is empirical. This gross estimate excludes denitrification credit and oxygen transfer.

Planning basis

WEF 11 and EPA process-control guidance place F/M and MCRT in the context of plant operations. SVI below 70 or above 150 mL/g prompts review for atypical settling. Confirm actual settling, clarity and oxygen demand with samples and site data.

Questions

Is low F/M alone proof of extended aeration performance?

Read it together with solids age, treatment objectives, loading variability and observed process performance.