WaterTreatLab

Biological treatment / Worked example

MCRT with Zero Entered Solids Loss

Explore undefined finite solids age when both WAS and effluent TSS are entered as zero.

Inputs

Aeration & food
MGD
mg/L
gal
mg/L
mg/L
mL/L
Solids leaving system
gpm
mg/L
mg/L
lb
E.g. secondary blanket
Oxygen demand
mg/L
mg/L as N
%

Results

US customary
F/M ratio
0.24 d⁻¹
MCRT / sludge age
No solids loss
Sludge volume index
100 mL/g
Actual oxygen demand
9,366.5 lb O₂/d 4,248.6 kg O₂/d
Aeration & solids returnLive diagram
Aeration & solids returnSolids inventory and wasting boundary. Return activated sludge remains in the system. Aeration tank3,200 mg/L MLSSSecondary clarifier100 mL/g SVIReturn sludge (RAS)Waste (WAS)— MCRT
Solids inventory and wasting boundary. Return activated sludge remains in the system.
Review the operating point
  • With no measured solids loss, a finite MCRT cannot be estimated.
Carbonaceous oxygen
6,164.9 lb O₂/d
Nitrification oxygen
3,201.6 lb O₂/d
Influent BOD₅ load
6,004.8 lb/d
Total solids inventory
35,860 lb
Wasted solids
0 lb/d
Effluent solids
0 lb/d

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Extra inventory increases the total to 33,360 + 2,500 = 35,860 lb.
  2. The entered WAS and effluent loss are both zero, so the modeled inventory-to-loss ratio has no finite result.

More worked examples

Equations & conventions

Food-to-microorganism ratio
F/M = (Q × BOD₅) / (V × MLVSS)

Use influent load to the aeration stage and the volatile mixed-liquor inventory. With consistent volume and concentration units the result is per day.

Solids retention time
MCRT = (V × MLSS + extra mass) / (QWAS × XWAS + Qeff × TSSₑ)

The calculator estimates effluent flow as influent minus WAS. Include measured clarifier solids in extra inventory if using the whole-train basis. RAS stays within the inventory boundary.

Sludge volume index
SVI = 1,000 × SV₃₀ / MLSS

Use 30-minute settled volume in mL/L and MLSS in mg/L. Compare time trends at the same test conditions.

Actual oxygen requirement
AOR = f꜀ × load(BOD₅ removed) + 4.57 × load(N oxidized)

The second term is optional. Use the fraction of incoming TKN expected to oxidize to nitrate. The carbon factor is empirical. This gross estimate excludes denitrification credit and oxygen transfer.

Planning basis

WEF 11 and EPA process-control guidance place F/M and MCRT in the context of plant operations. SVI below 70 or above 150 mL/g prompts review for atypical settling. Confirm actual settling, clarity and oxygen demand with samples and site data.

Questions

Why include a secondary blanket inventory in this example?

It shows how extra solids enter the numerator. A finite age still requires a measured daily loss across the system boundary.