WaterTreatLab

Biological treatment / Worked example

High SVI and the Bulking Screen

Use a 640 mL/L settling test and 3,000 mg/L MLSS to identify the high-SVI warning in an activated sludge case.

Inputs

Aeration & food
MGD
mg/L
gal
mg/L
mg/L
mL/L
Solids leaving system
gpm
mg/L
mg/L
lb
E.g. secondary blanket
Oxygen demand
mg/L
mg/L as N
%

Results

US customary
F/M ratio
0.27391 d⁻¹
MCRT / sludge age
8.1883 d
Sludge volume index
213.33 mL/g
Actual oxygen demand
14,162 lb O₂/d 6,423.6 kg O₂/d
Aeration & solids returnLive diagram
Aeration & solids returnSolids inventory and wasting boundary. Return activated sludge remains in the system. Aeration tank3,000 mg/L MLSSSecondary clarifier213.33 mL/g SVIReturn sludge (RAS)Waste (WAS)8.1883 d MCRT
Solids inventory and wasting boundary. Return activated sludge remains in the system.
Review the operating point
  • SVI is above 150 mL/g. Investigate bulking with a settling test, microscopy and blanket observations.
Carbonaceous oxygen
8,719 lb O₂/d
Nitrification oxygen
5,442.7 lb O₂/d
Influent BOD₅ load
8,406.7 lb/d
Total solids inventory
40,032 lb
Wasted solids
3,903.1 lb/d
Effluent solids
985.79 lb/d

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Divide 640 mL/L by 3 g/L MLSS. The SVI is 213.3 mL/g.
  2. WAS and effluent losses give an MCRT near 8.19 days. The high SVI calls for a site settling and solids review.

More worked examples

Equations & conventions

Food-to-microorganism ratio
F/M = (Q × BOD₅) / (V × MLVSS)

Use influent load to the aeration stage and the volatile mixed-liquor inventory. With consistent volume and concentration units the result is per day.

Solids retention time
MCRT = (V × MLSS + extra mass) / (QWAS × XWAS + Qeff × TSSₑ)

The calculator estimates effluent flow as influent minus WAS. Include measured clarifier solids in extra inventory if using the whole-train basis. RAS stays within the inventory boundary.

Sludge volume index
SVI = 1,000 × SV₃₀ / MLSS

Use 30-minute settled volume in mL/L and MLSS in mg/L. Compare time trends at the same test conditions.

Actual oxygen requirement
AOR = f꜀ × load(BOD₅ removed) + 4.57 × load(N oxidized)

The second term is optional. Use the fraction of incoming TKN expected to oxidize to nitrate. The carbon factor is empirical. This gross estimate excludes denitrification credit and oxygen transfer.

Planning basis

WEF 11 and EPA process-control guidance place F/M and MCRT in the context of plant operations. SVI below 70 or above 150 mL/g prompts review for atypical settling. Confirm actual settling, clarity and oxygen demand with samples and site data.

Questions

Does the high-SVI screen identify a filament by itself?

Use microscopy and other process observations to determine cause. SVI measures compaction under the settling test conditions.