150 ft² Dual-Media Filter Backwash

Size backwash pump flow, water use, bed expansion and air scour for a 150 ft² anthracite-over-sand cell.

Inputs

Filter cell
ft²
ft
ft
Zero uses the estimate
gal/d
Water backwash
gpm/ft²
°F
min
d⁻¹
Air scour
scfm/ft²
min

Results

US customary
Backwash pump flow
2,550 gpm
Water per wash
20,400 gal
Bed expansion
22.5 %
Daily UBRW
2.72 %
Filter bed fluidizationLive diagram
Filter bed fluidizationSettled and expanded bed profiles across the filter cell. Settled bed2.5 ftDuring wash3.0625 ftWater flow2,550 gpmExpansion22.5 %Air volume2,400 scf
Settled and expanded bed profiles across the filter cell.
Actual wash rise rate
17 gpm/ft² 41.561 m/h
Equivalent rise rate at 20 °C
17 gpm/ft² 41.561 m/h
Expanded depth
3.0625 ft
Daily washwater
20,400 gal/d
Air scour flow
600 scfm
Air volume per scour
2,400 scf
Water viscosity
1.0017 mPa·s

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. At 17 gpm/ft², the 150 ft² cell calls for 2,550 gpm and uses 20,400 gal in eight minutes.
  2. One wash divided by 750,000 gross gal/day uses 2.72% of daily production. Four minutes at 600 scfm uses 2,400 scf of air.

More worked examples

Equations & conventions

Rise rate and washwater
Qwash = A × v, Vwash = Qwash × t

The result is gpm with area in ft² and rise rate in gpm/ft². UBRW is 100 × daily washwater / gross daily production for the same cell.

Temperature adjustment
μ = 0.02414 × 10^(247.8/(Tc + 133.15)), vT = v₂₀ × (μ₂₀/μT)^0.35

μ is an approximate water viscosity in mPa·s. Select whether the input is already at wash temperature or is the reference at 20 °C. The exponent is a planning assumption chosen to approximate seasonal behavior.

Measured bed expansion
Expansion = 100 × (expanded depth / settled depth − 1)

Enter the total operating bed depth during wash. The settled and expanded depths exclude support gravel.

Modeled bed expansion
ε = min(0.80, εref × (v₂₀/vref)^(1/3)); E = 100 × max(0, (1−ε₀)/(1−ε) − 1)

The porosity screen uses ε₀ = 0.40 and εref = 1 − (1 − ε₀)/1.225. The illustrative 20 °C reference rates are 15/17/19 gpm/ft² for sand/dual/anthracite. Use measured depth or a media-specific curve for plant decisions.

Air scour
Air volume = specific standard airflow × A × air time

Report gas volume at the same standard conditions as the entered rate. The 3–5 scfm/ft² Ten States reference applies to underdrain introduction.

Planning basis

The EPA water-wash expansion reference is commonly 20–25% and varies with media and air scour. Verify the bed with a rise measurement or media supplier curve and check trough clearance. The model assumes discrete water and air volumes.

Questions

Why is calculated expansion 22.5% in this dual-media case?

The 17 gpm/ft² input matches the illustrative dual-media calibration point at 20 °C. Field data can replace the estimate.