WaterTreatLab

Granular filtration / Worked example

Warm Anthracite Backwash and Air Scour

Adjust anthracite wash rate to 25 °C and estimate air demand and daily water use for two cycles.

Inputs

Filter cell
ft²
ft
ft
Zero uses the estimate
gal/d
Water backwash
gpm/ft²
°F
min
d⁻¹
Air scour
scfm/ft²
min

Results

US customary
Backwash pump flow
2,376 gpm
Water per wash
16,632 gal
Bed expansion
22.5 %
Daily UBRW
6.6527 %
Filter bed fluidizationLive diagram
Filter bed fluidizationSettled and expanded bed profiles across the filter cell. Settled bed2.75 ftDuring wash3.3688 ftWater flow2,376 gpmExpansion22.5 %Air volume1,260 scf
Settled and expanded bed profiles across the filter cell.
Actual wash rise rate
19.8 gpm/ft² 48.405 m/h
Equivalent rise rate at 20 °C
19 gpm/ft² 46.45 m/h
Expanded depth
3.3688 ft
Daily washwater
33,263 gal/d
Air scour flow
420 scfm
Air volume per scour
1,260 scf
Water viscosity
0.89044 mPa·s

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Warmer water raises the adjusted rise rate from 19 to 19.80 gpm/ft². A seven-minute wash uses about 16,632 gal.
  2. Two washes use about 33,263 gal per day. Air scour is 3.5 × 120 × 3 = 1,260 scf per cycle.

More worked examples

Equations & conventions

Rise rate and washwater
Qwash = A × v, Vwash = Qwash × t

The result is gpm with area in ft² and rise rate in gpm/ft². UBRW is 100 × daily washwater / gross daily production for the same cell.

Temperature adjustment
μ = 0.02414 × 10^(247.8/(Tc + 133.15)), vT = v₂₀ × (μ₂₀/μT)^0.35

μ is an approximate water viscosity in mPa·s. Select whether the input is already at wash temperature or is the reference at 20 °C. The exponent is a planning assumption chosen to approximate seasonal behavior.

Measured bed expansion
Expansion = 100 × (expanded depth / settled depth − 1)

Enter the total operating bed depth during wash. The settled and expanded depths exclude support gravel.

Modeled bed expansion
ε = min(0.80, εref × (v₂₀/vref)^(1/3)); E = 100 × max(0, (1−ε₀)/(1−ε) − 1)

The porosity screen uses ε₀ = 0.40 and εref = 1 − (1 − ε₀)/1.225. The illustrative 20 °C reference rates are 15/17/19 gpm/ft² for sand/dual/anthracite. Use measured depth or a media-specific curve for plant decisions.

Air scour
Air volume = specific standard airflow × A × air time

Report gas volume at the same standard conditions as the entered rate. The 3–5 scfm/ft² Ten States reference applies to underdrain introduction.

Planning basis

The EPA water-wash expansion reference is commonly 20–25% and varies with media and air scour. Verify the bed with a rise measurement or media supplier curve and check trough clearance. The model assumes discrete water and air volumes.

Questions

Why is the air quantity shown per scour in this scenario?

One scour uses 1,260 scf under the entered standard conditions. Multiply by the number of scour events to budget a longer period.