UV Dose at the 100% UVT Limit

Check the Beer–Lambert limiting case at 100% UVT while keeping annular geometry and sleeve derating.

Inputs

Reactor & water
gpm
gal
%
cm
cm
mJ/cm²
Lamp & quartz sleeve
mW/cm²
%
%
W
Biodosimetry (optional)
Both zero leaves RED blank
log/(mJ/cm²)

Results

US customary
Modeled UV dose
44.928 mJ/cm²
Mean exposure
4.8 s
Lamps for model target
4
Power for model target
1.3 kW
Annular UV intensityLive diagram
Annular UV intensityRadial intensity drops with distance from the quartz sleeve. Annular cross-sectionRelative intensityUVT 100 %10Sleeve3 cmNew lampDerated44.928 mJ/cm²
Radial intensity drops with distance from the quartz sleeve.
Biodosimetry RED
Requires test data
Derated annular mean
9.36 mW/cm²
Absorption coefficient
0 cm⁻¹
Sleeve × EOLL factor
72 %
Water-gap transmission
100 %
Installed lamp power
1.3 kW

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. At 100% UVT, α = 0 and the absorption path average tends to one.
  2. The annular geometry still reduces the mean to half the sleeve-interface intensity before derating. Four lamps provide 44.928 mJ/cm² in the model.

More worked examples

Equations & conventions

Water attenuation
α = −ln(UVT/100) / 1 cm, I(x)/I₀ = r₀/(r₀+x) × e^(−αx)

Use UVT at 254 nm over a 1 cm cell. The model assumes a cylindrical lamp, uniform water and a representative annular gap.

Annular mean and exposure
Ī = I₀ × [2r₀/(2r₀+L)] × [1−e^(−αL)]/(αL) × sleeve × EOLL × N

The absorption term tends to one at 100% UVT. Exposure is illuminated volume divided by flow, in seconds. Modeled dose is Ī × exposure in mJ/cm².

Planning lamp count
Nneeded = ceil(target / dose per lamp), kW = Nneeded × W / 1,000

The model holds hydraulic exposure and the independent contribution per lamp fixed. Use clean, new-lamp sleeve-interface intensity before the entered fouling and aging factors.

Reduction equivalent dose
RED = observed log inactivation / calibrated bench slope

Optional test inputs require a measured reactor challenge result and a log-linear bench curve through the origin over that response range. Use the validated envelope and validation factors for regulatory credit.

Planning basis

The optical estimate assumes uniform axial flow and independent lamp contributions. Short circuiting, lamp arrangement, sensor response and the dose distribution require manufacturer validation. EPA RED comes from biodosimetry.

Questions

Why is the plotted intensity still lower at the outer wall in clear water?

Even at zero modeled absorption, intensity falls with radius in the cylindrical approximation.