Disinfection / Worked example

Fouled Quartz Sleeve and Aged Lamp

Apply separate 65% sleeve and 60% end-of-life lamp factors to estimate their combined impact on UV dose.

Inputs

Reactor & water
gpm
gal
%
cm
cm
mJ/cm²
Lamp & quartz sleeve
mW/cm²
%
%
W
Biodosimetry (optional)
Both zero leaves RED blank
log/(mJ/cm²)

Results

US customary
Modeled UV dose
20.213 mJ/cm²
Mean exposure
4.8 s
Lamps for model target
8
Power for model target
2.6 kW
Annular UV intensityLive diagram
Annular UV intensityRadial intensity drops with distance from the quartz sleeve. Annular cross-sectionRelative intensityUVT 88 %10Sleeve3 cmNew lampDerated20.213 mJ/cm²
Radial intensity drops with distance from the quartz sleeve.
Review the operating point
  • The modeled dose is below the entered planning target. Select a validated reactor for the required operating envelope.
Biodosimetry RED
Requires test data
Derated annular mean
4.211 mW/cm²
Absorption coefficient
0.12783 cm⁻¹
Sleeve × EOLL factor
39 %
Water-gap transmission
68.147 %
Installed lamp power
1.3 kW

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Combine 0.65 and 0.60 to get 0.39 of the clean, new-lamp intensity.
  2. At fixed flow, UVT and geometry that yields about 20.21 mJ/cm². Eight lamps would meet the modeled 40 mJ/cm² target at the entered efficiency.

More worked examples

Equations & conventions

Water attenuation
α = −ln(UVT/100) / 1 cm, I(x)/I₀ = r₀/(r₀+x) × e^(−αx)

Use UVT at 254 nm over a 1 cm cell. The model assumes a cylindrical lamp, uniform water and a representative annular gap.

Annular mean and exposure
Ī = I₀ × [2r₀/(2r₀+L)] × [1−e^(−αL)]/(αL) × sleeve × EOLL × N

The absorption term tends to one at 100% UVT. Exposure is illuminated volume divided by flow, in seconds. Modeled dose is Ī × exposure in mJ/cm².

Planning lamp count
Nneeded = ceil(target / dose per lamp), kW = Nneeded × W / 1,000

The model holds hydraulic exposure and the independent contribution per lamp fixed. Use clean, new-lamp sleeve-interface intensity before the entered fouling and aging factors.

Reduction equivalent dose
RED = observed log inactivation / calibrated bench slope

Optional test inputs require a measured reactor challenge result and a log-linear bench curve through the origin over that response range. Use the validated envelope and validation factors for regulatory credit.

Planning basis

The optical estimate assumes uniform axial flow and independent lamp contributions. Short circuiting, lamp arrangement, sensor response and the dose distribution require manufacturer validation. EPA RED comes from biodosimetry.

Questions

What is the difference between the 39% factor and UVT?

The 39% scales intensity from sleeve transmission and lamp age. Water UVT controls absorption as light travels away from the sleeve.