Automotive electronics case

AEC-Q100-style BGA solder cycling

A BGA sees 65 °C daily swing in service and 165 °C swing in the chamber. Translate 1,000 chamber cycles into a field-cycle target.

Inputs

°C
°C
cycles/day
cycles/day
°C
°C
eV
PassMission cycle goal met
Cycle AF
3.84615×
Field cycles
3,846.15
Field years
5.2687yr
Goal coverage
128.205%

Acceleration by test temperature swing

Thermal cycle acceleration versus test temperature swingThermal cycling · log₁₀ AF-0.9560.02931.0132.594.3156218Test swing ΔT (°C)Cycle AFEntered test

The curve varies chamber swing while holding the cycle rates and peak temperatures fixed. Its y-axis is logarithmic.

Download

Detailed results

Swing term
5.870622 ×
Frequency term
0.4404232 ×
Peak-temperature term
1.487553 ×
Mission cycle goal
3,000 cycles
Remaining field cycles
0 cycles

The chamber’s higher cycle frequency reduces the per-cycle multiplier under this fitted Norris–Landzberg model.

Formula trace

  1. Swing factor = (ΔTtest / ΔTuse)ᵐThe swing ratio contributes 5.870622×.
  2. Frequency factor = (fuse / ftest)ᵠThe cycle-rate ratio contributes 0.4404232×.
  3. Peak factor = exp[(Eₐ/k)(1/Tmax,use − 1/Tmax,test)]The peak-temperature term contributes 1.487553×.
  4. Field cycles = Ntest × AF · Years = Field cycles / (365 fuse)1,000 test cycles give 3,846.154 field cycles at 2 cycles/day.

Model assumptions

Use exponents fitted to the joint material, package and cycling profile. Frequency is cycles per day. Setting q and Eₐ to zero gives the simple swing-power Coffin–Manson approximation.