WeibullMTBFLab · Engineering calculation
QFN solder Coffin–Manson swing model
A QFN joint comparison uses only a squared swing ratio. The test has double the field swing and completes 750 cycles.
Mission cycle goal met
Inputs
- Field swing ΔT
- 55 °C
- Test swing ΔT
- 110 °C
- Field cycle frequency
- 1 cycles/day
- Test cycle frequency
- 20 cycles/day
- Field peak temperature
- 75 °C
- Test peak temperature
- 115 °C
- Swing exponent m
- 2
- Frequency exponent q
- 0
- Activation energy Eₐ
- 0 eV
- Completed test cycles
- 750
- Mission cycle goal
- 3,000
Results
- Cycle AF
- 4 ×
- Field cycles
- 3,000
- Field years
- 8.219178 yr
- Goal coverage
- 100 %
- Swing term
- 4 ×
- Frequency term
- 1 ×
- Peak-temperature term
- 1 ×
- Mission cycle goal
- 3,000 cycles
- Remaining field cycles
- 0 cycles
Swing factor = (ΔTtest / ΔTuse)ᵐThe swing ratio contributes 4×.Frequency factor = (fuse / ftest)ᵠThe cycle-rate ratio contributes 1×.Peak factor = exp[(Eₐ/k)(1/Tmax,use − 1/Tmax,test)]The peak-temperature term contributes 1×.Field cycles = Ntest × AF · Years = Field cycles / (365 fuse)750 test cycles give 3,000 field cycles at 1 cycles/day.
Use exponents fitted to the joint material, package and cycling profile. Frequency is cycles per day. Setting q and Eₐ to zero gives the simple swing-power Coffin–Manson approximation.