WeibullMTBFLab · Engineering calculation
Robot drive cold-start fatigue
A robot drive distribution board has a 72 °C use swing. A 130 °C chamber swing is used to assess 900 cycles against a field mission.
Mission cycle goal met
Inputs
- Field swing ΔT
- 72 °C
- Test swing ΔT
- 130 °C
- Field cycle frequency
- 3 cycles/day
- Test cycle frequency
- 16 cycles/day
- Field peak temperature
- 88 °C
- Test peak temperature
- 118 °C
- Swing exponent m
- 2.2
- Frequency exponent q
- 0.3
- Activation energy Eₐ
- 0.13 eV
- Completed test cycles
- 900
- Mission cycle goal
- 2,000
Results
- Cycle AF
- 3.059018 ×
- Field cycles
- 2,753.116
- Field years
- 2.514261 yr
- Goal coverage
- 137.65581442 %
- Swing term
- 3.668968 ×
- Frequency term
- 0.605202 ×
- Peak-temperature term
- 1.377646 ×
- Mission cycle goal
- 2,000 cycles
- Remaining field cycles
- 0 cycles
Swing factor = (ΔTtest / ΔTuse)ᵐThe swing ratio contributes 3.668968×.Frequency factor = (fuse / ftest)ᵠThe cycle-rate ratio contributes 0.605202×.Peak factor = exp[(Eₐ/k)(1/Tmax,use − 1/Tmax,test)]The peak-temperature term contributes 1.377646×.Field cycles = Ntest × AF · Years = Field cycles / (365 fuse)900 test cycles give 2,753.116 field cycles at 3 cycles/day.
Use exponents fitted to the joint material, package and cycling profile. Frequency is cycles per day. Setting q and Eₐ to zero gives the simple swing-power Coffin–Manson approximation.