Renewable energy case

Wind inverter low-amplitude chamber trial

A limited chamber trial uses a 52 °C test swing, below the 74 °C field swing, to verify the instrument’s coverage logic.

Inputs

°C
°C
cycles/day
cycles/day
°C
°C
eV
FailBelow mission cycle goal
Cycle AF
0.225665×
Field cycles
33.8498
Field years
0.030913yr
Goal coverage
2.25665%

Acceleration by test temperature swing

Thermal cycle acceleration versus test temperature swingThermal cycling · log₁₀ AF-1.42-0.6090.22645.765.485.1Test swing ΔT (°C)Cycle AFEntered test

The curve varies chamber swing while holding the cycle rates and peak temperatures fixed. Its y-axis is logarithmic.

Download

Detailed results

Swing term
0.5115241 ×
Frequency term
0.5346999 ×
Peak-temperature term
0.8250648 ×
Mission cycle goal
1,500 cycles
Remaining field cycles
1,466.15 cycles

Check how decelerating test conditions reduce equivalent field cycles and increase the remaining mission exposure.

Formula trace

  1. Swing factor = (ΔTtest / ΔTuse)ᵐThe swing ratio contributes 0.5115241×.
  2. Frequency factor = (fuse / ftest)ᵠThe cycle-rate ratio contributes 0.5346999×.
  3. Peak factor = exp[(Eₐ/k)(1/Tmax,use − 1/Tmax,test)]The peak-temperature term contributes 0.8250648×.
  4. Field cycles = Ntest × AF · Years = Field cycles / (365 fuse)150 test cycles give 33.84976 field cycles at 3 cycles/day.

Model assumptions

Use exponents fitted to the joint material, package and cycling profile. Frequency is cycles per day. Setting q and Eₐ to zero gives the simple swing-power Coffin–Manson approximation.

Method and sources

Related examples