Civil aviation case

Commercial avionics 2-out-of-3 voting

Three independent computing lanes have equal 20,000-hour MTBF. Two lanes are needed for the modeled function over 6,000 hours.

Inputs

h
h
h
Optional. Enter n values separated by commas.
PassSystem survival meets single-component reference
R system
83.3296%
F system
16.6704%
Survival gain
9.24774pp
MTTF multiple
0.833333×

System topology and reliability

Reliability block diagram and system versus reference survivalk-out-of-n2 of 3 requiredB1B2B3Mission survival0%50%100%01.3e42.7e44e4Time (h)SystemReferenceMission

The reference curve represents one component at the entered reference MTBF. Large topologies use representative blocks.

Download

Detailed results

System MTTF
16,666.67 h
Reference reliability
74.08182207 %
Required active blocks
2
Installed blocks
3

Compare this topology with series and active parallel using the same three inputs. Shared supplies and common causes require separate treatment.

Formula trace

  1. Rᵢ(t) = exp(−t / MTBFᵢ)The single-block reference at 6,000 h is 0.74081822.
  2. Rsys = ∑ⱼ₌ₖⁿ binomial(n,j) Rʲ (1−R)ⁿ⁻ʲThe topology gives Rsys = 0.83329559 and Fsys = 0.16670441.
  3. MTTFsys = ∫ Rsys(t) dt over t ≥ 0Mean system life is 16,666.67 h, or 0.8333333× reference MTBF.
  4. Survival gain = Rsys − RrefThe mission difference is 9.247737 percentage points.

Model assumptions

Blocks fail independently. Cold standby uses identical active failure rates, no dormant failures and perfect switching. Common-cause or imperfect switch failures require a separate model.