Industrial automation case

Robot drive cold-start fatigue

A robot drive distribution board has a 72 °C use swing. A 130 °C chamber swing is used to assess 900 cycles against a field mission.

Inputs

°C
°C
cycles/day
cycles/day
°C
°C
eV
PassMission cycle goal met
Cycle AF
3.05902×
Field cycles
2,753.12
Field years
2.51426yr
Goal coverage
137.656%

Acceleration by test temperature swing

Thermal cycle acceleration versus test temperature swingThermal cycling · log₁₀ AF-0.9410.004810.9513681.2126172Test swing ΔT (°C)Cycle AFEntered test

The curve varies chamber swing while holding the cycle rates and peak temperatures fixed. Its y-axis is logarithmic.

Download

Detailed results

Swing term
3.668968 ×
Frequency term
0.605202 ×
Peak-temperature term
1.377646 ×
Mission cycle goal
2,000 cycles
Remaining field cycles
0 cycles

Peak temperature and temperature swing enter separate factors. Switching temperature units preserves the Celsius-equivalent swing.

Formula trace

  1. Swing factor = (ΔTtest / ΔTuse)ᵐThe swing ratio contributes 3.668968×.
  2. Frequency factor = (fuse / ftest)ᵠThe cycle-rate ratio contributes 0.605202×.
  3. Peak factor = exp[(Eₐ/k)(1/Tmax,use − 1/Tmax,test)]The peak-temperature term contributes 1.377646×.
  4. Field cycles = Ntest × AF · Years = Field cycles / (365 fuse)900 test cycles give 2,753.116 field cycles at 3 cycles/day.

Model assumptions

Use exponents fitted to the joint material, package and cycling profile. Frequency is cycles per day. Setting q and Eₐ to zero gives the simple swing-power Coffin–Manson approximation.