WeibullMTBFLab · Engineering calculation
Server BGA power-cycle coverage
Compare an eight-cycle-per-day server power profile with a 36-cycle-per-day chamber profile. The test completes 800 cycles.
Below mission cycle goal
Inputs
- Field swing ΔT
- 40 °C
- Test swing ΔT
- 95 °C
- Field cycle frequency
- 8 cycles/day
- Test cycle frequency
- 36 cycles/day
- Field peak temperature
- 82 °C
- Test peak temperature
- 110 °C
- Swing exponent m
- 1.85
- Frequency exponent q
- 0.34
- Activation energy Eₐ
- 0.14 eV
- Completed test cycles
- 800
- Mission cycle goal
- 7,000
Results
- Cycle AF
- 4.150198 ×
- Field cycles
- 3,320.158
- Field years
- 1.13704 yr
- Goal coverage
- 47.43083139 %
- Swing term
- 4.954247 ×
- Frequency term
- 0.5996637 ×
- Peak-temperature term
- 1.396958 ×
- Mission cycle goal
- 7,000 cycles
- Remaining field cycles
- 3,679.842 cycles
Swing factor = (ΔTtest / ΔTuse)ᵐThe swing ratio contributes 4.954247×.Frequency factor = (fuse / ftest)ᵠThe cycle-rate ratio contributes 0.5996637×.Peak factor = exp[(Eₐ/k)(1/Tmax,use − 1/Tmax,test)]The peak-temperature term contributes 1.396958×.Field cycles = Ntest × AF · Years = Field cycles / (365 fuse)800 test cycles give 3,320.158 field cycles at 8 cycles/day.
Use exponents fitted to the joint material, package and cycling profile. Frequency is cycles per day. Setting q and Eₐ to zero gives the simple swing-power Coffin–Manson approximation.