WeibullMTBFLab · Engineering calculation
Wind inverter low-amplitude chamber trial
A limited chamber trial uses a 52 °C test swing, below the 74 °C field swing, to verify the instrument’s coverage logic.
Below mission cycle goal
Inputs
- Field swing ΔT
- 74 °C
- Test swing ΔT
- 52 °C
- Field cycle frequency
- 3 cycles/day
- Test cycle frequency
- 20 cycles/day
- Field peak temperature
- 100 °C
- Test peak temperature
- 82 °C
- Swing exponent m
- 1.9
- Frequency exponent q
- 0.33
- Activation energy Eₐ
- 0.122 eV
- Completed test cycles
- 150
- Mission cycle goal
- 1,500
Results
- Cycle AF
- 0.225665 ×
- Field cycles
- 33.84976
- Field years
- 0.03091302 yr
- Goal coverage
- 2.25665036 %
- Swing term
- 0.5115241 ×
- Frequency term
- 0.5346999 ×
- Peak-temperature term
- 0.8250648 ×
- Mission cycle goal
- 1,500 cycles
- Remaining field cycles
- 1,466.15 cycles
Swing factor = (ΔTtest / ΔTuse)ᵐThe swing ratio contributes 0.5115241×.Frequency factor = (fuse / ftest)ᵠThe cycle-rate ratio contributes 0.5346999×.Peak factor = exp[(Eₐ/k)(1/Tmax,use − 1/Tmax,test)]The peak-temperature term contributes 0.8250648×.Field cycles = Ntest × AF · Years = Field cycles / (365 fuse)150 test cycles give 33.84976 field cycles at 3 cycles/day.
Use exponents fitted to the joint material, package and cycling profile. Frequency is cycles per day. Setting q and Eₐ to zero gives the simple swing-power Coffin–Manson approximation.