WeldMetalLab

EN 1011-2 · Rosenthal

Fast T-fillet cooling and high crack flag

A highly restrained T connection combines fast cooling, elevated CE and an H16 scenario.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Thermal inputs
°C
kJ/mm
mm
Screening window
s
s
%

Live weld sheet

Updated from inputs
HAZ cooling curvePredicted t₈/₅ 1.84 s. Governing heat flow 3D. Transition thickness 9.58 mm. Cold-cracking flag Higher T₈/₅1.84sHEAT FLOW3DTRANSITION9.58mmCRACK FLAGHigher HAZ COOLING CURVE 800650500°Ctime →Start 20 °C3D · 1.84 s3D heat flow COOLING TIME WINDOWFAIL
Outside screen

Cooling time window · 7 s to 22 s entered for this steel.

Result details

Predicted t₈/₅1.84 s
Governing heat flow3D
Transition thickness9.58 mm
Cold-cracking flagHigher
2D cooling estimate0.25 s
3D cooling estimate1.84 s
Weld shape factor F₂0.55
Weld shape factor F₃0.67
Mean cooling rate162.82 °C/s
HAZ hardening tendencyHigher
Distance to nearest time bound-5.16 s

Worked example

Starting inputs

Seam shape
T-joint fillet
Starting temperature
20 °C
Effective heat input
0.52 kJ/mm
Plate thickness
26 mm
Minimum t₈/₅
7 s
Maximum t₈/₅
22 s
CE(IIW)
0.52 %

Baseline results

Predicted t₈/₅
1.84 s
Governing heat flow
3D
Transition thickness
9.58 mm
Cold-cracking flag
Higher

At 26 mm the 2D estimate is 0.25 s and the 3D estimate is 1.84 s. The transition at 9.58 mm selects the 3D result for the screen.

Try it. The combined flag is qualitative. Use it to identify a need for material-specific procedure and hardness review.

Calculation method

t₃ = (6700 − 5T₀)Q·Δ(1/T)·F₃ · t₂ = (4300 − 4.3T₀)10⁵(Q/d)²·Δ(1/T²)·F₂

Use temperature differences 500 − T₀ and 800 − T₀. Solve t₂ = t₃ for transition thickness. Below the transition, use the thin-plate 2D result. Above it, use the thick-plate 3D result. Seam factors are 1.0/1.0 for run on plate and 0.90/0.90 for butt welds. Corner and T-fillet 2D factors are midrange planning choices (0.80 and 0.55); both use 0.67 for 3D.

The qualitative hardening flag combines cooling below the entered minimum with CE(IIW) bands of 0.40 and 0.50. The cracking flag also adds hydrogen class and high restraint. Select cooling limits for the actual steel. Use grade-specific HAZ hardness, toughness and representative procedure tests for acceptance.