WeldMetalLab

EN 1011-2 · Rosenthal

Thick butt weld with 3D heat flow

A 1¼ in butt weld is screened for HAZ cooling with a starting temperature of 150 °F.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Thermal inputs
°F
kJ/in
in
Screening window
s
s
%

Live weld sheet

Updated from inputs
HAZ cooling curvePredicted t₈/₅ 4.85 s. Governing heat flow 3D. Transition thickness 0.57 in. Cold-cracking flag Higher T₈/₅4.85sHEAT FLOW3DTRANSITION0.57inCRACK FLAGHigher HAZ COOLING CURVE 1,4721,202932°Ftime →Start 150 °F3D · 4.85 s3D heat flow COOLING TIME WINDOWFAIL
Outside screen

Cooling time window · 6 s to 25 s entered for this steel.

Result details

Predicted t₈/₅4.85 s
Governing heat flow3D
Transition thickness0.57 in
Cold-cracking flagHigher
2D cooling estimate1 s
3D cooling estimate4.85 s
Weld shape factor F₂0.9
Weld shape factor F₃0.9
Mean cooling rate111.27 °F/s
HAZ hardening tendencyHigher
Distance to nearest time bound-1.15 s

Worked example

Starting inputs

Seam shape
Butt weld
Starting temperature
150 °F
Effective heat input
22.86 kJ/in
Plate thickness
1.25 in
Minimum t₈/₅
6 s
Maximum t₈/₅
25 s
CE(IIW)
0.44 %

Baseline results

Predicted t₈/₅
4.85 s
Governing heat flow
3D
Transition thickness
0.57 in
Cold-cracking flag
Higher

At 1.25 in the 2D estimate is 1 s and the 3D estimate is 4.85 s. The transition at 0.57 in selects the 3D result for the screen.

Try it. Moving farther above transition thickness leaves the governing 3D result unchanged at fixed heat and temperature.

Calculation method

t₃ = (6700 − 5T₀)Q·Δ(1/T)·F₃ · t₂ = (4300 − 4.3T₀)10⁵(Q/d)²·Δ(1/T²)·F₂

Use temperature differences 500 − T₀ and 800 − T₀. Solve t₂ = t₃ for transition thickness. Below the transition, use the thin-plate 2D result. Above it, use the thick-plate 3D result. Seam factors are 1.0/1.0 for run on plate and 0.90/0.90 for butt welds. Corner and T-fillet 2D factors are midrange planning choices (0.80 and 0.55); both use 0.67 for 3D.

The qualitative hardening flag combines cooling below the entered minimum with CE(IIW) bands of 0.40 and 0.50. The cracking flag also adds hydrogen class and high restraint. Select cooling limits for the actual steel. Use grade-specific HAZ hardness, toughness and representative procedure tests for acceptance.

References

More worked examples