WeldMetalLab

EN 1011-2 · Rosenthal

Thin plate with 2D cooling

A run on a thin plate starts at 80 °C. Heat spreads primarily in the plane of the plate over the interval.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Thermal inputs
°C
kJ/mm
mm
Screening window
s
s
%

Live weld sheet

Updated from inputs
HAZ cooling curvePredicted t₈/₅ 16.98 s. Governing heat flow 2D. Transition thickness 13.32 mm. Cold-cracking flag Lower T₈/₅16.98sHEAT FLOW2DTRANSITION13.32mmCRACK FLAGLower HAZ COOLING CURVE 800650500°Ctime →Start 80 °C2D · 16.98 s2D heat flow COOLING TIME WINDOWPASS
Pass · within screen

Cooling time window · 6 s to 30 s entered for this steel.

Result details

Predicted t₈/₅16.98 s
Governing heat flow2D
Transition thickness13.32 mm
Cold-cracking flagLower
2D cooling estimate16.98 s
3D cooling estimate4.69 s
Weld shape factor F₂1
Weld shape factor F₃1
Mean cooling rate17.66 °C/s
HAZ hardening tendencyLower
Distance to nearest time bound10.98 s

Worked example

Starting inputs

Seam shape
Run on plate
Starting temperature
80 °C
Effective heat input
0.75 kJ/mm
Plate thickness
7 mm
Minimum t₈/₅
6 s
Maximum t₈/₅
30 s
CE(IIW)
0.35 %

Baseline results

Predicted t₈/₅
16.98 s
Governing heat flow
2D
Transition thickness
13.32 mm
Cold-cracking flag
Lower

At 7 mm the 2D estimate is 16.98 s and the 3D estimate is 4.69 s. The transition at 13.32 mm selects the 2D result for the screen.

Try it. Increase thickness to the transition. The 2D estimate approaches the 3D estimate from above.

Calculation method

t₃ = (6700 − 5T₀)Q·Δ(1/T)·F₃ · t₂ = (4300 − 4.3T₀)10⁵(Q/d)²·Δ(1/T²)·F₂

Use temperature differences 500 − T₀ and 800 − T₀. Solve t₂ = t₃ for transition thickness. Below the transition, use the thin-plate 2D result. Above it, use the thick-plate 3D result. Seam factors are 1.0/1.0 for run on plate and 0.90/0.90 for butt welds. Corner and T-fillet 2D factors are midrange planning choices (0.80 and 0.55); both use 0.67 for 3D.

The qualitative hardening flag combines cooling below the entered minimum with CE(IIW) bands of 0.40 and 0.50. The cracking flag also adds hydrogen class and high restraint. Select cooling limits for the actual steel. Use grade-specific HAZ hardness, toughness and representative procedure tests for acceptance.

References

More worked examples