EN 1011-2 · Rosenthal
Thick butt weld with 3D heat flow
A 1¼ in butt weld is screened for HAZ cooling with a starting temperature of 150 °F.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsCooling time window · 6 s to 25 s entered for this steel.
Result details
| Predicted t₈/₅ | 4.85 s |
|---|---|
| Governing heat flow | 3D |
| Transition thickness | 0.57 in |
| Cold-cracking flag | Higher |
| 2D cooling estimate | 1 s |
| 3D cooling estimate | 4.85 s |
| Weld shape factor F₂ | 0.9 |
| Weld shape factor F₃ | 0.9 |
| Mean cooling rate | 111.27 °F/s |
| HAZ hardening tendency | Higher |
| Distance to nearest time bound | -1.15 s |
Worked example
Starting inputs
- Seam shape
- Butt weld
- Starting temperature
- 150 °F
- Effective heat input
- 22.86 kJ/in
- Plate thickness
- 1.25 in
- Minimum t₈/₅
- 6 s
- Maximum t₈/₅
- 25 s
- CE(IIW)
- 0.44 %
Baseline results
- Predicted t₈/₅
- 4.85 s
- Governing heat flow
- 3D
- Transition thickness
- 0.57 in
- Cold-cracking flag
- Higher
At 1.25 in the 2D estimate is 1 s and the 3D estimate is 4.85 s. The transition at 0.57 in selects the 3D result for the screen.
Try it. Moving farther above transition thickness leaves the governing 3D result unchanged at fixed heat and temperature.
Calculation method
t₃ = (6700 − 5T₀)Q·Δ(1/T)·F₃ · t₂ = (4300 − 4.3T₀)10⁵(Q/d)²·Δ(1/T²)·F₂
Use temperature differences 500 − T₀ and 800 − T₀. Solve t₂ = t₃ for transition thickness. Below the transition, use the thin-plate 2D result. Above it, use the thick-plate 3D result. Seam factors are 1.0/1.0 for run on plate and 0.90/0.90 for butt welds. Corner and T-fillet 2D factors are midrange planning choices (0.80 and 0.55); both use 0.67 for 3D.
The qualitative hardening flag combines cooling below the entered minimum with CE(IIW) bands of 0.40 and 0.50. The cracking flag also adds hydrogen class and high restraint. Select cooling limits for the actual steel. Use grade-specific HAZ hardness, toughness and representative procedure tests for acceptance.