Worked example
10-Gallon ATO Reservoir Runtime for a Reef Tank
The ATO reservoir holds 10 usable US gallons after allowing for the pump’s minimum level. The reef loses 0.8 gallon a day in warm conditions.
See the worked calculationInputs
Results
Edit inputs10-Gallon ATO Reservoir Runtime for a Reef Tank
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/10-gallon-ato-reservoir-runtime-reef-tank/
- ATO reservoir runtime
- 12.5 days
- Free volume after cutoff
- 5.32 US gal
- Sump turnover per hour
- 6 ×
Calculation details
- Screened drain capacity
- 633 US gal/h
- Screened flow with one drain blocked
- 317 US gal/h
- Return at 3× turnover
- 330 US gal/h
- Return at 10× turnover
- 1,100 US gal/h
- Total power-off drain-down
- 5.44 US gal
- Theoretical freeboard storage
- 10.76 US gal
- Power-off rise in sump
- 2.02 in
- Free volume after selected allowance
- 3.69 US gal
- Return flow exceeds the screened drain capacity. Reduce flow and verify the drain system.
- Confirm the result during a supervised outage and restart test.
Input measurements
- Display inside length
- 48 in
- Display inside width
- 24 in
- Actual display water
- 110 US gal
- Delivered return flow
- 660 US gal/h
- Counted drains
- 2
- Actual pipe inside diameter
- 1.04724 in
- Effective inlet head
- 2 in
- Inlet discharge coefficient
- 0.6
- Drop until the weir stops
- 0.5 in
- Drop until return siphon breaks
- 0.85 in
- Additional draining pipes and box
- 1.2 US gal
- Sump usable inside length
- 35.5 in
- Sump usable inside width
- 17.5 in
- Normal level to lowest spill point
- 4 in
- Extra allowance above drain-down
- 30 %
- Usable freshwater reservoir
- 10 US gal
- Observed daily evaporation
- 0.8 US gal/day
Supervise a real power-off and restart test before relying on the sump. Test the emergency drain and ATO cutoffs, and confirm salinity with a calibrated instrument before returning the system to livestock use.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Find the power-off water volume
(48 in × 24 in) × 0.85 in → 4.24 US gal; + 1.2 US gal = 5.44 US gal
Use the larger of the weir and siphon drops. Add the extra water draining outside the display footprint.
Compare it with sump freeboard
10.76 US gal freeboard − 5.44 US gal drain-down = 5.32 US gal remaining
Subtract 1.63 US gal of planned reserve for a margin of 3.69 US gal.
Screen the drain and return
Q per drain = 0.6 × π × (26.6 mm ÷ 2)² × √(2g × 5.08 cm) → 317 US gal/h
Use consistent SI units in the orifice formula. 2 drain paths screen at 633 US gal/h. 660 US gal/h ÷ 110 US gal gives 6× per hour.
Estimate top-off runtime
10 US gal ÷ 0.8 US gal/day → 12.5 days
Time the reservoir against actual evaporation and its usable cutoff level.
Frequently asked questions
Should I top off the 10-gallon reservoir with new saltwater?
Use suitable freshwater for ordinary evaporation. Salt stays behind in the tank as water evaporates. Check salinity with a calibrated instrument.
Why does the ATO reservoir run dry sooner than its advertised size suggests?
The suction point and low-level protection leave part of the reservoir unused. Measure the actual water delivered between full and cutoff.