Worked example
120-Gallon Reef Dual Drains with One Blocked
A 120-gallon net display uses two modeled 1.25 in ID drain paths and a 720 GPH return. Compare the two-opening estimate with the same system after one path is blocked.
See the worked calculationInputs
Results
Edit inputs120-Gallon Reef Dual Drains with One Blocked
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/120-gallon-reef-two-overflow-drains-one-blocked/
- Screened flow with one drain blocked
- 504 US gal/h
- Free volume after cutoff
- 7.03 US gal
- Sump turnover per hour
- 6 ×
Calculation details
- ATO reservoir runtime
- 15.4 days
- Screened drain capacity
- 1,008 US gal/h
- Return at 3× turnover
- 360 US gal/h
- Return at 10× turnover
- 1,200 US gal/h
- Total power-off drain-down
- 5.44 US gal
- Theoretical freeboard storage
- 12.47 US gal
- Power-off rise in sump
- 1.74 in
- Free volume after selected allowance
- 5.4 US gal
- With one drain blocked, the remaining screened capacity is below the return flow. Verify the emergency overflow can carry the full return flow.
- Confirm the result during a supervised outage and restart test.
Input measurements
- Display inside length
- 48 in
- Display inside width
- 24 in
- Actual display water
- 120 US gal
- Delivered return flow
- 720 US gal/h
- Counted drains
- 2
- Actual pipe inside diameter
- 1.25 in
- Effective inlet head
- 2.5 in
- Inlet discharge coefficient
- 0.6
- Drop until the weir stops
- 0.5 in
- Drop until return siphon breaks
- 0.85 in
- Additional draining pipes and box
- 1.2 US gal
- Sump usable inside length
- 40 in
- Sump usable inside width
- 18 in
- Normal level to lowest spill point
- 4 in
- Extra allowance above drain-down
- 30 %
- Usable freshwater reservoir
- 10 US gal
- Observed daily evaporation
- 0.65 US gal/day
Supervise a real power-off and restart test before relying on the sump. Test the emergency drain and ATO cutoffs, and confirm salinity with a calibrated instrument before returning the system to livestock use.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Find the power-off water volume
(48 in × 24 in) × 0.85 in → 4.24 US gal; + 1.2 US gal = 5.44 US gal
Use the larger of the weir and siphon drops. Add the extra water draining outside the display footprint.
Compare it with sump freeboard
12.47 US gal freeboard − 5.44 US gal drain-down = 7.03 US gal remaining
Subtract 1.63 US gal of planned reserve for a margin of 5.4 US gal.
Screen the drain and return
Q per drain = 0.6 × π × (31.75 mm ÷ 2)² × √(2g × 6.35 cm) → 504 US gal/h
Use consistent SI units in the orifice formula. 2 drain paths screen at 1,008 US gal/h. 720 US gal/h ÷ 120 US gal gives 6× per hour.
Estimate top-off runtime
10 US gal ÷ 0.65 US gal/day → 15.38 days
Time the reservoir against actual evaporation and its usable cutoff level.
Frequently asked questions
Do two overflow drains give measurable redundancy on a 120-gallon reef?
There is redundancy only if the remaining path can accept the actual return flow under its real conditions. Test the main path blocked with supervision.
When should a dry emergency drain be included in a capacity calculation?
Include it only for an operating scenario where it is submerged as designed and its performance is verified. Ordinary running capacity excludes a dry path.