Tank engineering

Sump Overflow, Return Pump & Flood Margin Calculator

Estimate drain pipe flow, sump turnover, return siphon drain-down, power outage flood margin and ATO reservoir runtime.

Inputs

View results
Display and return
in
in
US gal
US gal/h

Use the pump curve at total head or a flow measurement.

Identical parallel drains

Count paths that can independently take flow. Exclude dry emergency paths if you do not know their capacity.

in
in

Water head across the inlet in the modeled condition.

0.60 models a sharp opening. Calibrate with a flow test.

Power-off reserve
in
in

Test without relying on a check valve.

US gal

Count trapped volumes outside the display footprint.

in
in
in

Use the area available for rising water across compartments.

%
Auto top-off
US gal
US gal/day
Free volume after cutoff
5.32 US gal
Sump turnover per hour
6 ×
ATO reservoir runtime
15.4 days
Operating and power-off sump levelsNormal freeboard 4 in. The water rises 2.02 in when the return stops. Sump sectionLowest spill pointPower-off rise2.02 inVolume after cutoff5.3 US galNormal levelPower-off level
Normal & power-off sump levels

Calculation details

Screened drain capacity
633 US gal/h
Screened flow with one drain blocked
317 US gal/h
Return at 3× turnover
330 US gal/h
Return at 10× turnover
1,100 US gal/h
Total power-off drain-down
5.44 US gal
Theoretical freeboard storage
10.76 US gal
Power-off rise in sump
2.02 in
Free volume after selected allowance
3.69 US gal
  • Return flow exceeds the screened drain capacity. Reduce flow and verify the drain system.
  • Confirm the result during a supervised outage and restart test.

Input measurements

Display inside length
48 in
Display inside width
24 in
Actual display water
110 US gal
Delivered return flow
660 US gal/h
Counted drains
2
Actual pipe inside diameter
1.04724 in
Effective inlet head
2 in
Inlet discharge coefficient
0.6
Drop until the weir stops
0.5 in
Drop until return siphon breaks
0.85 in
Additional draining pipes and box
1.2 US gal
Sump usable inside length
35.5 in
Sump usable inside width
17.5 in
Normal level to lowest spill point
4 in
Extra allowance above drain-down
30 %
Usable freshwater reservoir
10 US gal
Observed daily evaporation
0.65 US gal/day

Supervise a real power-off and restart test before relying on the sump. Test the emergency drain and ATO cutoffs, and confirm salinity with a calibrated instrument before returning the system to livestock use.

How the calculation works

The drain screening model uses an orifice estimate per pipe, Cd × area × √(2g × inlet head). It omits bends, pipe friction, air entrainment, blockage and overflow box restrictions. Verify delivered return flow and each emergency drain in operation.

The display drains to whichever is deeper, the weir stop or the return siphon break. Multiply that drop by the display area and add the separately measured water from pipes and the overflow box. Sump freeboard times usable area gives theoretical storage.

Compare delivered return flow with 3–10 times measured display volume per hour as a planning band. Internal circulation pumps are separate. ATO runtime divides usable reservoir water by observed daily evaporation.

References

Frequently asked questions

Should a return check valve count toward the sump flood margin?

Plan for a check valve that leaks or sticks open. Test where the return siphon actually stops, and reserve enough space for that volume plus your allowance.

Is return pump turnover the same as total in-tank circulation?

Return turnover describes flow through the sump. Powerheads can supply much of the display’s circulation without pushing additional water through the drains.