Tank engineering
Sump Overflow, Return Pump & Flood Margin Calculator
Estimate drain pipe flow, sump turnover, return siphon drain-down, power outage flood margin and ATO reservoir runtime.
Inputs
Results
Edit inputsSump Overflow, Return Pump & Flood Margin Calculator
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/sump-overflow-return-pump-turnover-evaporation-calculator/
- Free volume after cutoff
- 5.32 US gal
- Sump turnover per hour
- 6 ×
- ATO reservoir runtime
- 15.4 days
Calculation details
- Screened drain capacity
- 633 US gal/h
- Screened flow with one drain blocked
- 317 US gal/h
- Return at 3× turnover
- 330 US gal/h
- Return at 10× turnover
- 1,100 US gal/h
- Total power-off drain-down
- 5.44 US gal
- Theoretical freeboard storage
- 10.76 US gal
- Power-off rise in sump
- 2.02 in
- Free volume after selected allowance
- 3.69 US gal
- Return flow exceeds the screened drain capacity. Reduce flow and verify the drain system.
- Confirm the result during a supervised outage and restart test.
Input measurements
- Display inside length
- 48 in
- Display inside width
- 24 in
- Actual display water
- 110 US gal
- Delivered return flow
- 660 US gal/h
- Counted drains
- 2
- Actual pipe inside diameter
- 1.04724 in
- Effective inlet head
- 2 in
- Inlet discharge coefficient
- 0.6
- Drop until the weir stops
- 0.5 in
- Drop until return siphon breaks
- 0.85 in
- Additional draining pipes and box
- 1.2 US gal
- Sump usable inside length
- 35.5 in
- Sump usable inside width
- 17.5 in
- Normal level to lowest spill point
- 4 in
- Extra allowance above drain-down
- 30 %
- Usable freshwater reservoir
- 10 US gal
- Observed daily evaporation
- 0.65 US gal/day
Supervise a real power-off and restart test before relying on the sump. Test the emergency drain and ATO cutoffs, and confirm salinity with a calibrated instrument before returning the system to livestock use.
How the calculation works
The drain screening model uses an orifice estimate per pipe, Cd × area × √(2g × inlet head). It omits bends, pipe friction, air entrainment, blockage and overflow box restrictions. Verify delivered return flow and each emergency drain in operation.
The display drains to whichever is deeper, the weir stop or the return siphon break. Multiply that drop by the display area and add the separately measured water from pipes and the overflow box. Sump freeboard times usable area gives theoretical storage.
Compare delivered return flow with 3–10 times measured display volume per hour as a planning band. Internal circulation pumps are separate. ATO runtime divides usable reservoir water by observed daily evaporation.
References
Frequently asked questions
Should a return check valve count toward the sump flood margin?
Plan for a check valve that leaks or sticks open. Test where the return siphon actually stops, and reserve enough space for that volume plus your allowance.
Is return pump turnover the same as total in-tank circulation?
Return turnover describes flow through the sump. Powerheads can supply much of the display’s circulation without pushing additional water through the drains.