Worked example

1-Inch Aquarium Overflow Drain GPH at 2 Inches of Head

This example measures a 26.6 mm inside diameter in one nominal 1-inch PVC drain. Use two inches of effective head and a 0.60 inlet discharge coefficient.

See the worked calculation

Inputs

View results
Display and return
in
in
US gal
US gal/h

Use the pump curve at total head or a flow measurement.

Identical parallel drains

Count paths that can independently take flow. Exclude dry emergency paths if you do not know their capacity.

in
in

Water head across the inlet in the modeled condition.

0.60 models a sharp opening. Calibrate with a flow test.

Power-off reserve
in
in

Test without relying on a check valve.

US gal

Count trapped volumes outside the display footprint.

in
in
in

Use the area available for rising water across compartments.

%
Auto top-off
US gal
US gal/day
Screened drain capacity
317 US gal/h
Free volume after cutoff
5.32 US gal
Sump turnover per hour
5.8 ×
Operating and power-off sump levelsNormal freeboard 4 in. The water rises 2.02 in when the return stops. Sump sectionLowest spill pointPower-off rise2.02 inVolume after cutoff5.3 US galNormal levelPower-off level
Normal & power-off sump levels

Calculation details

ATO reservoir runtime
15.4 days
Screened flow with one drain blocked
0 US gal/h
Return at 3× turnover
180 US gal/h
Return at 10× turnover
600 US gal/h
Total power-off drain-down
5.44 US gal
Theoretical freeboard storage
10.76 US gal
Power-off rise in sump
2.02 in
Free volume after selected allowance
3.69 US gal
  • Return flow exceeds the screened drain capacity. Reduce flow and verify the drain system.
  • Confirm the result during a supervised outage and restart test.

Input measurements

Display inside length
48 in
Display inside width
24 in
Actual display water
60 US gal
Delivered return flow
350 US gal/h
Counted drains
1
Actual pipe inside diameter
1.04724 in
Effective inlet head
2 in
Inlet discharge coefficient
0.6
Drop until the weir stops
0.5 in
Drop until return siphon breaks
0.85 in
Additional draining pipes and box
1.2 US gal
Sump usable inside length
35.5 in
Sump usable inside width
17.5 in
Normal level to lowest spill point
4 in
Extra allowance above drain-down
30 %
Usable freshwater reservoir
10 US gal
Observed daily evaporation
0.65 US gal/day

Supervise a real power-off and restart test before relying on the sump. Test the emergency drain and ATO cutoffs, and confirm salinity with a calibrated instrument before returning the system to livestock use.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Find the power-off water volume

    (48 in × 24 in) × 0.85 in → 4.24 US gal; + 1.2 US gal = 5.44 US gal

    Use the larger of the weir and siphon drops. Add the extra water draining outside the display footprint.

  2. Compare it with sump freeboard

    10.76 US gal freeboard − 5.44 US gal drain-down = 5.32 US gal remaining

    Subtract 1.63 US gal of planned reserve for a margin of 3.69 US gal.

  3. Screen the drain and return

    Q per drain = 0.6 × π × (26.6 mm ÷ 2)² × √(2g × 5.08 cm) → 317 US gal/h

    Use consistent SI units in the orifice formula. 1 drain path screen at 317 US gal/h. 350 US gal/h ÷ 60 US gal gives 5.83× per hour.

  4. Estimate top-off runtime

    10 US gal ÷ 0.65 US gal/day → 15.38 days

    Time the reservoir against actual evaporation and its usable cutoff level.

Frequently asked questions

Why is the inside diameter not exactly one inch for this PVC drain?

Nominal pipe size is a trade size. Actual bore varies by pipe schedule and material. Use the inside diameter from your pipe or its datasheet.

Does doubling inlet head double a 1-inch drain’s flow estimate?

No. The screening calculation uses the square root of head. Doubling head multiplies the estimate by about 1.41 for the same opening and coefficient.