Worked example
75-Gallon Aquarium Return Pump at 6× Turnover
The running display contains 75 US gallons and the return actually delivers 450 GPH. Compare the delivered flow with the return planning band and drain screen.
See the worked calculationInputs
Results
Edit inputs75-Gallon Aquarium Return Pump at 6× Turnover
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/75-gallon-aquarium-return-pump-six-times-turnover/
- Sump turnover per hour
- 6 ×
- Free volume after cutoff
- 6.5 US gal
- ATO reservoir runtime
- 15.4 days
Calculation details
- Screened drain capacity
- 633 US gal/h
- Screened flow with one drain blocked
- 317 US gal/h
- Return at 3× turnover
- 225 US gal/h
- Return at 10× turnover
- 750 US gal/h
- Total power-off drain-down
- 4.26 US gal
- Theoretical freeboard storage
- 10.76 US gal
- Power-off rise in sump
- 1.58 in
- Free volume after selected allowance
- 5.22 US gal
- With one drain blocked, the remaining screened capacity is below the return flow. Verify the emergency overflow can carry the full return flow.
- Confirm the result during a supervised outage and restart test.
Input measurements
- Display inside length
- 47.5 in
- Display inside width
- 17.5 in
- Actual display water
- 75 US gal
- Delivered return flow
- 450 US gal/h
- Counted drains
- 2
- Actual pipe inside diameter
- 1.04724 in
- Effective inlet head
- 2 in
- Inlet discharge coefficient
- 0.6
- Drop until the weir stops
- 0.5 in
- Drop until return siphon breaks
- 0.85 in
- Additional draining pipes and box
- 1.2 US gal
- Sump usable inside length
- 35.5 in
- Sump usable inside width
- 17.5 in
- Normal level to lowest spill point
- 4 in
- Extra allowance above drain-down
- 30 %
- Usable freshwater reservoir
- 10 US gal
- Observed daily evaporation
- 0.65 US gal/day
Supervise a real power-off and restart test before relying on the sump. Test the emergency drain and ATO cutoffs, and confirm salinity with a calibrated instrument before returning the system to livestock use.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Find the power-off water volume
(47.5 in × 17.5 in) × 0.85 in → 3.06 US gal; + 1.2 US gal = 4.26 US gal
Use the larger of the weir and siphon drops. Add the extra water draining outside the display footprint.
Compare it with sump freeboard
10.76 US gal freeboard − 4.26 US gal drain-down = 6.5 US gal remaining
Subtract 1.28 US gal of planned reserve for a margin of 5.22 US gal.
Screen the drain and return
Q per drain = 0.6 × π × (26.6 mm ÷ 2)² × √(2g × 5.08 cm) → 317 US gal/h
Use consistent SI units in the orifice formula. 2 drain paths screen at 633 US gal/h. 450 US gal/h ÷ 75 US gal gives 6× per hour.
Estimate top-off runtime
10 US gal ÷ 0.65 US gal/day → 15.38 days
Time the reservoir against actual evaporation and its usable cutoff level.
Frequently asked questions
How should I measure 450 GPH if my pump only lists its zero-head flow?
Use an inline flowmeter or safely time a known discharge volume. For a consistent single outlet, one US gallon every eight seconds is about 450 GPH.
Does an internal 450 GPH powerhead add to the 75-gallon sump turnover?
No. A display powerhead recirculates water within the tank. Count only the flow the return sends from the sump back to the display.