Worked example

75-Gallon Aquarium Return Pump at 6× Turnover

The running display contains 75 US gallons and the return actually delivers 450 GPH. Compare the delivered flow with the return planning band and drain screen.

See the worked calculation

Inputs

View results
Display and return
in
in
US gal
US gal/h

Use the pump curve at total head or a flow measurement.

Identical parallel drains

Count paths that can independently take flow. Exclude dry emergency paths if you do not know their capacity.

in
in

Water head across the inlet in the modeled condition.

0.60 models a sharp opening. Calibrate with a flow test.

Power-off reserve
in
in

Test without relying on a check valve.

US gal

Count trapped volumes outside the display footprint.

in
in
in

Use the area available for rising water across compartments.

%
Auto top-off
US gal
US gal/day
Sump turnover per hour
6 ×
Free volume after cutoff
6.5 US gal
ATO reservoir runtime
15.4 days
Operating and power-off sump levelsNormal freeboard 4 in. The water rises 1.58 in when the return stops. Sump sectionLowest spill pointPower-off rise1.58 inVolume after cutoff6.5 US galNormal levelPower-off level
Normal & power-off sump levels

Calculation details

Screened drain capacity
633 US gal/h
Screened flow with one drain blocked
317 US gal/h
Return at 3× turnover
225 US gal/h
Return at 10× turnover
750 US gal/h
Total power-off drain-down
4.26 US gal
Theoretical freeboard storage
10.76 US gal
Power-off rise in sump
1.58 in
Free volume after selected allowance
5.22 US gal
  • With one drain blocked, the remaining screened capacity is below the return flow. Verify the emergency overflow can carry the full return flow.
  • Confirm the result during a supervised outage and restart test.

Input measurements

Display inside length
47.5 in
Display inside width
17.5 in
Actual display water
75 US gal
Delivered return flow
450 US gal/h
Counted drains
2
Actual pipe inside diameter
1.04724 in
Effective inlet head
2 in
Inlet discharge coefficient
0.6
Drop until the weir stops
0.5 in
Drop until return siphon breaks
0.85 in
Additional draining pipes and box
1.2 US gal
Sump usable inside length
35.5 in
Sump usable inside width
17.5 in
Normal level to lowest spill point
4 in
Extra allowance above drain-down
30 %
Usable freshwater reservoir
10 US gal
Observed daily evaporation
0.65 US gal/day

Supervise a real power-off and restart test before relying on the sump. Test the emergency drain and ATO cutoffs, and confirm salinity with a calibrated instrument before returning the system to livestock use.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Find the power-off water volume

    (47.5 in × 17.5 in) × 0.85 in → 3.06 US gal; + 1.2 US gal = 4.26 US gal

    Use the larger of the weir and siphon drops. Add the extra water draining outside the display footprint.

  2. Compare it with sump freeboard

    10.76 US gal freeboard − 4.26 US gal drain-down = 6.5 US gal remaining

    Subtract 1.28 US gal of planned reserve for a margin of 5.22 US gal.

  3. Screen the drain and return

    Q per drain = 0.6 × π × (26.6 mm ÷ 2)² × √(2g × 5.08 cm) → 317 US gal/h

    Use consistent SI units in the orifice formula. 2 drain paths screen at 633 US gal/h. 450 US gal/h ÷ 75 US gal gives 6× per hour.

  4. Estimate top-off runtime

    10 US gal ÷ 0.65 US gal/day → 15.38 days

    Time the reservoir against actual evaporation and its usable cutoff level.

Frequently asked questions

How should I measure 450 GPH if my pump only lists its zero-head flow?

Use an inline flowmeter or safely time a known discharge volume. For a consistent single outlet, one US gallon every eight seconds is about 450 GPH.

Does an internal 450 GPH powerhead add to the 75-gallon sump turnover?

No. A display powerhead recirculates water within the tank. Count only the flow the return sends from the sump back to the display.