Worked example
Deep Return Nozzle Siphon and Sump Overflow Risk
A 48 × 24 in display drains 0.5 in through its weir but continues to siphon down to 2.5 in at the return. The smaller sump has only 3 in before its lowest spill point.
See the worked calculationInputs
Results
Edit inputsDeep Return Nozzle Siphon and Sump Overflow Risk
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/deep-return-nozzle-siphon-sump-overflow-risk/
- Free volume after cutoff
- -8.94 US gal
- Sump turnover per hour
- 6 ×
- ATO reservoir runtime
- 15.4 days
Calculation details
- Screened drain capacity
- 633 US gal/h
- Screened flow with one drain blocked
- 317 US gal/h
- Return at 3× turnover
- 330 US gal/h
- Return at 10× turnover
- 1,100 US gal/h
- Total power-off drain-down
- 13.27 US gal
- Theoretical freeboard storage
- 4.33 US gal
- Power-off rise in sump
- 9.19 in
- Free volume after selected allowance
- -12.92 US gal
- Predicted spill. The modeled drain-down exceeds freeboard.
- Return flow exceeds the screened drain capacity. Reduce flow and verify the drain system.
- Confirm the result during a supervised outage and restart test.
Input measurements
- Display inside length
- 48 in
- Display inside width
- 24 in
- Actual display water
- 110 US gal
- Delivered return flow
- 660 US gal/h
- Counted drains
- 2
- Actual pipe inside diameter
- 1.04724 in
- Effective inlet head
- 2 in
- Inlet discharge coefficient
- 0.6
- Drop until the weir stops
- 0.5 in
- Drop until return siphon breaks
- 2.5 in
- Additional draining pipes and box
- 0.8 US gal
- Sump usable inside length
- 29 in
- Sump usable inside width
- 11.5 in
- Normal level to lowest spill point
- 3 in
- Extra allowance above drain-down
- 30 %
- Usable freshwater reservoir
- 10 US gal
- Observed daily evaporation
- 0.65 US gal/day
Supervise a real power-off and restart test before relying on the sump. Test the emergency drain and ATO cutoffs, and confirm salinity with a calibrated instrument before returning the system to livestock use.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Find the power-off water volume
(48 in × 24 in) × 2.5 in → 12.47 US gal; + 0.8 US gal = 13.27 US gal
Use the larger of the weir and siphon drops. Add the extra water draining outside the display footprint.
Compare it with sump freeboard
4.33 US gal freeboard − 13.27 US gal drain-down = -8.94 US gal remaining
Subtract 3.98 US gal of planned reserve for a margin of -12.92 US gal.
Screen the drain and return
Q per drain = 0.6 × π × (26.6 mm ÷ 2)² × √(2g × 5.08 cm) → 317 US gal/h
Use consistent SI units in the orifice formula. 2 drain paths screen at 633 US gal/h. 660 US gal/h ÷ 110 US gal gives 6× per hour.
Estimate top-off runtime
10 US gal ÷ 0.65 US gal/day → 15.38 days
Time the reservoir against actual evaporation and its usable cutoff level.
Frequently asked questions
Do I add the 0.5 in weir drop to the 2.5 in return siphon drop?
Use the deeper drop. Both drain the same display water, so adding the depth amounts would count the first half inch twice.
What does a negative sump margin tell me about the deep return?
The modeled power-off water volume exceeds the sump’s storage. Reconfigure the siphon break or sump operating level and verify with an outage test.