Worked example

Deep Return Nozzle Siphon and Sump Overflow Risk

A 48 × 24 in display drains 0.5 in through its weir but continues to siphon down to 2.5 in at the return. The smaller sump has only 3 in before its lowest spill point.

See the worked calculation

Inputs

View results
Display and return
in
in
US gal
US gal/h

Use the pump curve at total head or a flow measurement.

Identical parallel drains

Count paths that can independently take flow. Exclude dry emergency paths if you do not know their capacity.

in
in

Water head across the inlet in the modeled condition.

0.60 models a sharp opening. Calibrate with a flow test.

Power-off reserve
in
in

Test without relying on a check valve.

US gal

Count trapped volumes outside the display footprint.

in
in
in

Use the area available for rising water across compartments.

%
Auto top-off
US gal
US gal/day
Free volume after cutoff
-8.94 US gal
Sump turnover per hour
6 ×
ATO reservoir runtime
15.4 days
Operating and power-off sump levelsNormal freeboard 3 in. The water rises 9.19 in when the return stops. Sump sectionLowest spill pointPower-off rise9.19 inVolume after cutoff-8.9 US galNormal levelPower-off level
Normal & power-off sump levels

Calculation details

Screened drain capacity
633 US gal/h
Screened flow with one drain blocked
317 US gal/h
Return at 3× turnover
330 US gal/h
Return at 10× turnover
1,100 US gal/h
Total power-off drain-down
13.27 US gal
Theoretical freeboard storage
4.33 US gal
Power-off rise in sump
9.19 in
Free volume after selected allowance
-12.92 US gal
  • Predicted spill. The modeled drain-down exceeds freeboard.
  • Return flow exceeds the screened drain capacity. Reduce flow and verify the drain system.
  • Confirm the result during a supervised outage and restart test.

Input measurements

Display inside length
48 in
Display inside width
24 in
Actual display water
110 US gal
Delivered return flow
660 US gal/h
Counted drains
2
Actual pipe inside diameter
1.04724 in
Effective inlet head
2 in
Inlet discharge coefficient
0.6
Drop until the weir stops
0.5 in
Drop until return siphon breaks
2.5 in
Additional draining pipes and box
0.8 US gal
Sump usable inside length
29 in
Sump usable inside width
11.5 in
Normal level to lowest spill point
3 in
Extra allowance above drain-down
30 %
Usable freshwater reservoir
10 US gal
Observed daily evaporation
0.65 US gal/day

Supervise a real power-off and restart test before relying on the sump. Test the emergency drain and ATO cutoffs, and confirm salinity with a calibrated instrument before returning the system to livestock use.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Find the power-off water volume

    (48 in × 24 in) × 2.5 in → 12.47 US gal; + 0.8 US gal = 13.27 US gal

    Use the larger of the weir and siphon drops. Add the extra water draining outside the display footprint.

  2. Compare it with sump freeboard

    4.33 US gal freeboard − 13.27 US gal drain-down = -8.94 US gal remaining

    Subtract 3.98 US gal of planned reserve for a margin of -12.92 US gal.

  3. Screen the drain and return

    Q per drain = 0.6 × π × (26.6 mm ÷ 2)² × √(2g × 5.08 cm) → 317 US gal/h

    Use consistent SI units in the orifice formula. 2 drain paths screen at 633 US gal/h. 660 US gal/h ÷ 110 US gal gives 6× per hour.

  4. Estimate top-off runtime

    10 US gal ÷ 0.65 US gal/day → 15.38 days

    Time the reservoir against actual evaporation and its usable cutoff level.

Frequently asked questions

Do I add the 0.5 in weir drop to the 2.5 in return siphon drop?

Use the deeper drop. Both drain the same display water, so adding the depth amounts would count the first half inch twice.

What does a negative sump margin tell me about the deep return?

The modeled power-off water volume exceeds the sump’s storage. Reconfigure the siphon break or sump operating level and verify with an outage test.