Worked example
Clay basement pit with battered sides
A basement excavation has a 44 × 30 ft bottom including working space. The pit model expands both top dimensions with a 0.75H:1V geometry input.
Estimate
Bank excavation · BCY
- Use site-specific swell and shrink factors. Excavation protection and payload limits require a separate site review.
- Loose excavation · LCY
- 846.113 yd³
- Available compacted fill · CCY
- 564.075 yd³
- Loose-volume truck trips
- 57
- Top opening width
- 43.5 ft
- Top opening length
- 57.5 ft
- Compacted surplus or deficit
- 424.075 yd³
- Bank borrow needed
- 0 yd³
Download
Working this example
Starting estimate 626.75 yd³Bank excavation · BCY
Use the working excavation footprint, which includes room for the construction detail and access requirements.
Questions & answers
What is the top opening of this battered basement pit?
Each side grows 0.75 × 9 = 6.75 ft from bottom to top. The opening is 57.5 × 43.5 ft.
Why use a midpoint area for the clay basement pit?
Both plan dimensions change with depth, so plan area changes quadratically. The prismoidal formula accounts for that curvature.