Worked example
Square-side trench quantity from a shored detail
The volume takeoff uses the vertical geometry shown on a site-specific shoring detail, over a 72 ft trench with a 4.5 ft bottom.
Estimate
Bank excavation · BCY
- Use site-specific swell and shrink factors. Excavation protection and payload limits require a separate site review.
- Loose excavation · LCY
- 110.88 yd³
- Available compacted fill · CCY
- 74.76 yd³
- Loose-volume truck trips
- 11
- Top opening width
- 4.5 ft
- Top opening length
- 72 ft
- Compacted surplus or deficit
- 20.76 yd³
- Bank borrow needed
- 0 yd³
Download
Working this example
Starting estimate 84 yd³Bank excavation · BCY
Confirm net excavation width against the actual shoring envelope and installation sequence.
Questions & answers
What volume formula does zero batter give for this shored trench?
The section reduces to a rectangle. 72 × 4.5 × 7 gives 2,268 ft³, or 84 BCY.
Is a zero-batter input a shoring selection for the trench?
It describes the volume geometry. The actual protective system depends on the approved site-specific plan.