Eighty percent depth cutout screen
An inspection finds 8.0 mm of loss in a 10.0 mm nominal sound wall. The axial extent is 280 mm.
Inputs
SI unitsEnter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.
- Burst pressure
- —
- Safe pressure
- —
- ERF
- —
- Wall loss
- 80 %
Axial metal-loss profile
SchematicMetal loss is at least 80% of wall. Escalate for immediate integrity disposition. No safe-pressure estimate is reported for this case.
Calculation details
- Length parameter z
- 15.433
- Original Folias M
- 3.653
- Modified Folias M
- 3.143
- Selected pressure result
- —
- Original flow stress
- 394.38 MPa
- Modified flow stress
- 427.47 MPa
- Original predicted failure
- —
- Modified predicted failure
- —
- Original safe pressure
- —
- Modified safe pressure
- —
- Intact-wall design cap
- 10,162.98 kPa
- Screened pressure minus MAOP
- —
Inputs used
- Governing method
- Lower of both methods
- Outside diameter
- 508 mm
- Sound wall thickness
- 10 mm
- Pipe grade SMYS
- 358.52738 MPa
- Design factor F
- 0.72
- Operating MAOP
- 6,500 kPa
- Metal-loss depth
- 8 mm
- Axial defect length
- 280 mm
Worked calculation
Starting values · SI- Depth ratio is 80%. The length parameter z is 15.43307.
- The 80% screen has priority. The safe pressure and ERF are withheld.
- Send the verified defect dimensions and operating conditions for integrity disposition.
The fixed 80% screen takes priority over pressure calculations and withholds the safe-pressure value.
Method and limits
Calculate the loss and length ratios
Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.
Evaluate the two profiles
Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.
Screen the pressure
For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.