CorrosionRateLab
Menu

Eighty percent depth cutout screen

An inspection finds 8.0 mm of loss in a 10.0 mm nominal sound wall. The axial extent is 280 mm.

Inputs

SI units

Enter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.

mm
mm
MPa
kPa
mm
mm
Burst pressure
—
Safe pressure
—
ERF
—
Wall loss
80 %

Axial metal-loss profile

Schematic
Axial metal-loss profile (schematic, not to scale)Outside surfaceAxial sectionPipe boreDepth limit reachedAXIAL EXTENT280 mmLOSS DEPTH8 mmSOUND WALL10 mm
Immediate repair / cutout screen

Metal loss is at least 80% of wall. Escalate for immediate integrity disposition. No safe-pressure estimate is reported for this case.

Depth has reached the 80% wall limit

Calculation details

Length parameter z
15.433
Original Folias M
3.653
Modified Folias M
3.143
Selected pressure result
—
Original flow stress
394.38 MPa
Modified flow stress
427.47 MPa
Original predicted failure
—
Modified predicted failure
—
Original safe pressure
—
Modified safe pressure
—
Intact-wall design cap
10,162.98 kPa
Screened pressure minus MAOP
—

Worked calculation

Starting values · SI
  1. Depth ratio is 80%. The length parameter z is 15.43307.
  2. The 80% screen has priority. The safe pressure and ERF are withheld.
  3. Send the verified defect dimensions and operating conditions for integrity disposition.

The fixed 80% screen takes priority over pressure calculations and withholds the safe-pressure value.

Method and limits

  1. Calculate the loss and length ratios

    Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.

  2. Evaluate the two profiles

    Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.

  3. Screen the pressure

    For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.