CorrosionRateLab
Menu

Sound pipe and intact design cap

The evaluation location has no measured wall loss or axial defect.

Inputs

SI units

Enter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.

mm
mm
MPa
kPa
mm
mm
Burst pressure
14,789.25 kPa
Safe pressure
9,680.24 kPa
ERF
0.671
Wall loss
0 %

Axial metal-loss profile

Schematic
Axial metal-loss profile (schematic, not to scale)Outside surfaceAxial sectionPipe boreSound wall datumAXIAL EXTENT0 mmLOSS DEPTH0 mmSOUND WALL9.53 mm
Within pressure screen

The entered MAOP fits the selected pressure screen. Verify the defect profile, interactions, safety factor and jurisdiction before disposition.

MAOP ÷ screened safe pressure · limit 1.00

Calculation details

Length parameter z
0
Original Folias M
1
Modified Folias M
1
Selected pressure result
Original B31G
Original flow stress
394.38 MPa
Modified flow stress
427.47 MPa
Original predicted failure
14,789.25 kPa
Modified predicted failure
16,030.31 kPa
Original safe pressure
9,680.24 kPa
Modified safe pressure
9,680.24 kPa
Intact-wall design cap
9,680.24 kPa
Screened pressure minus MAOP
3,180.24 kPa

Worked calculation

Starting values · SI
  1. Depth ratio is 0%. The length parameter z is 0.
  2. Original and Modified failure estimates are 14,789.25439 and 16,030.31071 kPa, respectively.
  3. With F = 0.72, the selected safe pressure is 9,680.23924 kPa and ERF is 0.67147.

Flow stress still affects the calculated burst estimate. The displayed safe pressure is bounded by the intact design pressure.

Method and limits

  1. Calculate the loss and length ratios

    Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.

  2. Evaluate the two profiles

    Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.

  3. Screen the pressure

    For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.