MAOP above the corrosion screen
A long, deep defect was measured on a line operating at 9,500 kPa. The deepest point is 5.5 mm.
Inputs
SI unitsEnter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.
- Burst pressure
- 6,249.53 kPa
- Safe pressure
- 4,499.66 kPa
- ERF
- 2.111
- Wall loss
- 57.74 %
Axial metal-loss profile
SchematicEscalate the finding for qualified integrity assessment. Confirm operating pressure, material and measured defect profile.
Calculation details
- Length parameter z
- 34.741
- Original Folias M
- —
- Modified Folias M
- 4.327
- Selected pressure result
- Original B31G
- Original flow stress
- 394.38 MPa
- Modified flow stress
- 427.47 MPa
- Original predicted failure
- 6,249.53 kPa
- Modified predicted failure
- 9,206.63 kPa
- Original safe pressure
- 4,499.66 kPa
- Modified safe pressure
- 6,628.77 kPa
- Intact-wall design cap
- 9,680.24 kPa
- Screened pressure minus MAOP
- -5,000.34 kPa
Inputs used
- Governing method
- Lower of both methods
- Outside diameter
- 508 mm
- Sound wall thickness
- 9.525 mm
- Pipe grade SMYS
- 358.52738 MPa
- Design factor F
- 0.72
- Operating MAOP
- 9,500 kPa
- Metal-loss depth
- 5.5 mm
- Axial defect length
- 410 mm
Worked calculation
Starting values · SI- Depth ratio is 57.74278%. The length parameter z is 34.74074.
- Original and Modified failure estimates are 6,249.52745 and 9,206.62922 kPa, respectively.
- With F = 0.72, the selected safe pressure is 4,499.65976 kPa and ERF is 2.11127.
An ERF above 1 signals a failed pressure screen. The model calls for a qualified integrity assessment.
Method and limits
Calculate the loss and length ratios
Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.
Evaluate the two profiles
Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.
Screen the pressure
For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.