CorrosionRateLab
Menu

MAOP above the corrosion screen

A long, deep defect was measured on a line operating at 9,500 kPa. The deepest point is 5.5 mm.

Inputs

SI units

Enter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.

mm
mm
MPa
kPa
mm
mm
Burst pressure
6,249.53 kPa
Safe pressure
4,499.66 kPa
ERF
2.111
Wall loss
57.74 %

Axial metal-loss profile

Schematic
Axial metal-loss profile (schematic, not to scale)Outside surfaceAxial sectionPipe boreSound wall datumAXIAL EXTENT410 mmLOSS DEPTH5.5 mmSOUND WALL9.53 mm
MAOP exceeds pressure screen

Escalate the finding for qualified integrity assessment. Confirm operating pressure, material and measured defect profile.

MAOP ÷ screened safe pressure · limit 1.00

Calculation details

Length parameter z
34.741
Original Folias M
—
Modified Folias M
4.327
Selected pressure result
Original B31G
Original flow stress
394.38 MPa
Modified flow stress
427.47 MPa
Original predicted failure
6,249.53 kPa
Modified predicted failure
9,206.63 kPa
Original safe pressure
4,499.66 kPa
Modified safe pressure
6,628.77 kPa
Intact-wall design cap
9,680.24 kPa
Screened pressure minus MAOP
-5,000.34 kPa

Worked calculation

Starting values · SI
  1. Depth ratio is 57.74278%. The length parameter z is 34.74074.
  2. Original and Modified failure estimates are 6,249.52745 and 9,206.62922 kPa, respectively.
  3. With F = 0.72, the selected safe pressure is 4,499.65976 kPa and ERF is 2.11127.

An ERF above 1 signals a failed pressure screen. The model calls for a qualified integrity assessment.

Method and limits

  1. Calculate the loss and length ratios

    Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.

  2. Evaluate the two profiles

    Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.

  3. Screen the pressure

    For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.