A 500 mm OD pipe with 10 mm wall thickness has a 500 mm axial corrosion length and 3 mm depth.

Inputs

SI units

Enter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.

mm
mm
MPa
kPa
mm
mm
Burst pressure
13,439.2 kPa
Safe pressure
9,676.22 kPa
ERF
0.672
Wall loss
30 %

Axial metal-loss profile

Schematic
Axial metal-loss profile (schematic, not to scale)Outside surfaceAxial sectionPipe boreSound wall datumAXIAL EXTENT500 mmLOSS DEPTH3 mmSOUND WALL10 mm
Within pressure screen

The entered MAOP fits the selected pressure screen. Verify the defect profile, interactions, safety factor and jurisdiction before disposition.

MAOP ÷ screened safe pressure · limit 1.00

Calculation details

Length parameter z
50
Original Folias M
—
Modified Folias M
4.893
Selected pressure result
Modified B31G
Original flow stress
394.38 MPa
Modified flow stress
427.47 MPa
Original predicted failure
11,042.64 kPa
Modified predicted failure
13,439.2 kPa
Original safe pressure
7,950.7 kPa
Modified safe pressure
9,676.22 kPa
Intact-wall design cap
10,325.59 kPa
Screened pressure minus MAOP
3,176.22 kPa

Worked calculation

Starting values · SI
  1. Depth ratio is 30%. The length parameter z is 50.
  2. Original and Modified failure estimates are 11,042.64328 and 13,439.19877 kPa, respectively.
  3. With F = 0.72, the selected safe pressure is 9,676.22312 kPa and ERF is 0.67175.

The polynomial Folias factor applies at equality. Increase length slightly to see the modified linear branch.

Method and limits

  1. Calculate the loss and length ratios

    Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.

  2. Evaluate the two profiles

    Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.

  3. Screen the pressure

    For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.