Original B31G at z = 20
A 200 mm OD pipe with a 10 mm wall has a 200 mm axial defect. These dimensions give z = 20.
Inputs
SI unitsEnter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.
- Burst pressure
- 35,321.85 kPa
- Safe pressure
- 25,431.73 kPa
- ERF
- 0.256
- Wall loss
- 20 %
Axial metal-loss profile
SchematicThe entered MAOP fits the selected pressure screen. Verify the defect profile, interactions, safety factor and jurisdiction before disposition.
Calculation details
- Length parameter z
- 20
- Original Folias M
- 4.123
- Modified Folias M
- 3.493
- Selected pressure result
- Original B31G
- Original flow stress
- 394.38 MPa
- Modified flow stress
- 427.47 MPa
- Original predicted failure
- 35,321.85 kPa
- Modified predicted failure
- 37,295.63 kPa
- Original safe pressure
- 25,431.73 kPa
- Modified safe pressure
- 25,813.97 kPa
- Intact-wall design cap
- 25,813.97 kPa
- Screened pressure minus MAOP
- 18,931.73 kPa
Inputs used
- Governing method
- Original B31G
- Outside diameter
- 200 mm
- Sound wall thickness
- 10 mm
- Pipe grade SMYS
- 358.52738 MPa
- Design factor F
- 0.72
- Operating MAOP
- 6,500 kPa
- Metal-loss depth
- 2 mm
- Axial defect length
- 200 mm
Worked calculation
Starting values · SI- Depth ratio is 20%. The length parameter z is 20.
- Original and Modified failure estimates are 35,321.85112 and 37,295.63143 kPa, respectively.
- With F = 0.72, the selected safe pressure is 25,431.73281 kPa and ERF is 0.25559.
At the branch boundary, use the original short-defect expression. A longer defect is evaluated by the original long-defect term.
Method and limits
Calculate the loss and length ratios
Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.
Evaluate the two profiles
Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.
Screen the pressure
For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.