CorrosionRateLab
Menu

Original B31G at z = 20

A 200 mm OD pipe with a 10 mm wall has a 200 mm axial defect. These dimensions give z = 20.

Inputs

SI units

Enter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.

mm
mm
MPa
kPa
mm
mm
Burst pressure
35,321.85 kPa
Safe pressure
25,431.73 kPa
ERF
0.256
Wall loss
20 %

Axial metal-loss profile

Schematic
Axial metal-loss profile (schematic, not to scale)Outside surfaceAxial sectionPipe boreSound wall datumAXIAL EXTENT200 mmLOSS DEPTH2 mmSOUND WALL10 mm
Within pressure screen

The entered MAOP fits the selected pressure screen. Verify the defect profile, interactions, safety factor and jurisdiction before disposition.

MAOP ÷ screened safe pressure · limit 1.00

Calculation details

Length parameter z
20
Original Folias M
4.123
Modified Folias M
3.493
Selected pressure result
Original B31G
Original flow stress
394.38 MPa
Modified flow stress
427.47 MPa
Original predicted failure
35,321.85 kPa
Modified predicted failure
37,295.63 kPa
Original safe pressure
25,431.73 kPa
Modified safe pressure
25,813.97 kPa
Intact-wall design cap
25,813.97 kPa
Screened pressure minus MAOP
18,931.73 kPa

Worked calculation

Starting values · SI
  1. Depth ratio is 20%. The length parameter z is 20.
  2. Original and Modified failure estimates are 35,321.85112 and 37,295.63143 kPa, respectively.
  3. With F = 0.72, the selected safe pressure is 25,431.73281 kPa and ERF is 0.25559.

At the branch boundary, use the original short-defect expression. A longer defect is evaluated by the original long-defect term.

Method and limits

  1. Calculate the loss and length ratios

    Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.

  2. Evaluate the two profiles

    Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.

  3. Screen the pressure

    For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.