CorrosionRateLab
Menu

Final anode current governs

A coated 700 m² structure has low mean demand but a high final breakdown factor and a resistive electrolyte.

Inputs

SI units

Enter bare-metal design current density for each phase and its associated coating breakdown. Use final stand-off anode dimensions.

m²
yr
%
mA/m²
%
mA/m²
%
mA/m²
%
kg
m
m
V
Ω·m
Required mass
108.21 kg
Anodes needed
97
Output / anode
0.44 A
Capacity life
784.34 yr

Galvanic current field

Schematic
Galvanic current field (schematic, not to scale)Anode metalProtected steelConventional current through electrolyteDRIVING VOLTAGE0.25 VFINAL DEMAND42.56 AANODE OUTPUT0.44 A
Final current governs

Confirm final geometry, closed-circuit potentials, coating allowances and current distribution with the CP design basis.

Final demand ÷ modeled installed output

Calculation details

Alloy design capacity
2,000 A·h/kg
Initial demand
4.48 A
Mean demand
0.84 A
Final demand
42.56 A
Final single-anode resistance
0.5656 Ω
Count by net mass
4
Count by final current
97
Count for initial polarization
11
Installed net mass
3,395 kg
Total installed current output
42.88 A

Worked calculation

Starting values · SI
  1. Initial, mean and final current demands are 4.48, 0.84 and 42.56 A.
  2. Mean demand and 2,000 A·h/kg capacity give 108.21176 kg required alloy mass.
  3. Final resistance is 0.5656 Ω with 0.44201 A per anode. Count by mass is 4, by final current 97 and by initial current 11.

Initial net mass would allow fewer anodes than the final current demand. End-of-life current governs this screen.

Method and limits

  1. Estimate demand at three stages

    For each stage, demand = protected area × coating breakdown × corresponding bare current density. Convert percent to a fraction and mA/m² to A/m².

  2. Calculate net alloy mass

    M = mean demand × 8,760 × design years ÷ (capacity × utilization). Divide by net mass per anode and round up. Preset capacities are 2,000, 780 and 1,100 A·h/kg for aluminum, zinc and magnesium, respectively.

  3. Check final and initial current

    For a slender stand-off anode, R = ρ[ln(4L/r) − 1]/(2πL), with L ≥ 4r. Current per anode is ΔE/R. Round final demand divided by single-anode current up and select the larger of the mass and final current counts. The additional initial screen uses the same final geometry as a conservative check.