Zinc anodes for a brackish structure
A 340 m² coated frame uses 32 kg zinc anodes in 0.65 Ω·m water. Design life is 16 years.
Inputs
SI unitsEnter bare-metal design current density for each phase and its associated coating breakdown. Use final stand-off anode dimensions.
- Required mass
- 575.02 kg
- Anodes needed
- 18
- Output / anode
- 0.58 A
- Capacity life
- 16.03 yr
Galvanic current field
SchematicConfirm final geometry, closed-circuit potentials, coating allowances and current distribution with the CP design basis.
Calculation details
- Alloy design capacity
- 780 A·h/kg
- Initial demand
- 2.18 A
- Mean demand
- 2.72 A
- Final demand
- 8.16 A
- Final single-anode resistance
- 0.3082 Ω
- Count by net mass
- 18
- Count by final current
- 14
- Count for initial polarization
- 4
- Installed net mass
- 576 kg
- Total installed current output
- 10.51 A
Inputs used
- Anode alloy
- Zinc
- Protected area
- 340 m²
- Design life
- 16 yr
- Initial breakdown
- 4 %
- Initial bare demand
- 160 mA/m²
- Mean breakdown
- 8 %
- Mean bare demand
- 100 mA/m²
- Final breakdown
- 15 %
- Final bare demand
- 160 mA/m²
- Utilization
- 85 %
- Net mass per anode
- 32 kg
- Final anode length
- 1.15 m
- Final equiv. radius
- 0.055 m
- Driving voltage ΔE
- 0.18 V
- Electrolyte resistivity
- 0.65 Ω·m
Worked calculation
Starting values · SI- Initial, mean and final current demands are 2.176, 2.72 and 8.16 A.
- Mean demand and 780 A·h/kg capacity give 575.01538 kg required alloy mass.
- Final resistance is 0.30824 Ω with 0.58397 A per anode. Count by mass is 18, by final current 14 and by initial current 4.
Compare the lower zinc capacity with its available driving voltage under the project’s closed-circuit potential assumptions.
Method and limits
Estimate demand at three stages
For each stage, demand = protected area × coating breakdown × corresponding bare current density. Convert percent to a fraction and mA/m² to A/m².
Calculate net alloy mass
M = mean demand × 8,760 × design years ÷ (capacity × utilization). Divide by net mass per anode and round up. Preset capacities are 2,000, 780 and 1,100 A·h/kg for aluminum, zinc and magnesium, respectively.
Check final and initial current
For a slender stand-off anode, R = ρ[ln(4L/r) − 1]/(2πL), with L ≥ 4r. Current per anode is ΔE/R. Round final demand divided by single-anode current up and select the larger of the mass and final current counts. The additional initial screen uses the same final geometry as a conservative check.