Zero entered coating breakdown
All three coating breakdown inputs were entered as zero for a coated frame.
Inputs
SI unitsEnter bare-metal design current density for each phase and its associated coating breakdown. Use final stand-off anode dimensions.
- Required mass
- 0 kg
- Anodes needed
- 0
- Output / anode
- 2.65 A
- Capacity life
- —
Galvanic current field
SchematicConfirm the coating and exposed area assumptions before omitting protection.
Calculation details
- Alloy design capacity
- 2,000 A·h/kg
- Initial demand
- 0 A
- Mean demand
- 0 A
- Final demand
- 0 A
- Final single-anode resistance
- 0.0942 Ω
- Count by net mass
- 0
- Count by final current
- 0
- Count for initial polarization
- 0
- Installed net mass
- 0 kg
- Total installed current output
- 0 A
Inputs used
- Anode alloy
- Aluminum–zinc–indium
- Protected area
- 1,200 m²
- Design life
- 25 yr
- Initial breakdown
- 0 %
- Initial bare demand
- 160 mA/m²
- Mean breakdown
- 0 %
- Mean bare demand
- 100 mA/m²
- Final breakdown
- 0 %
- Final bare demand
- 160 mA/m²
- Utilization
- 85 %
- Net mass per anode
- 55 kg
- Final anode length
- 1.6 m
- Final equiv. radius
- 0.08 m
- Driving voltage ΔE
- 0.25 V
- Electrolyte resistivity
- 0.28 Ω·m
Worked calculation
Starting values · SI- Initial, mean and final current demands are 0, 0 and 0 A.
- Mean demand and 2,000 A·h/kg capacity give 0 kg required alloy mass.
- Final resistance is 0.0942 Ω with 2.65402 A per anode. Count by mass is 0, by final current 0 and by initial current 0.
Arithmetic returns a zero required count and no capacity life. Confirm that coating damage and exposed details are included in the design basis.
Method and limits
Estimate demand at three stages
For each stage, demand = protected area × coating breakdown × corresponding bare current density. Convert percent to a fraction and mA/m² to A/m².
Calculate net alloy mass
M = mean demand × 8,760 × design years ÷ (capacity × utilization). Divide by net mass per anode and round up. Preset capacities are 2,000, 780 and 1,100 A·h/kg for aluminum, zinc and magnesium, respectively.
Check final and initial current
For a slender stand-off anode, R = ρ[ln(4L/r) − 1]/(2πL), with L ≥ 4r. Current per anode is ΔE/R. Round final demand divided by single-anode current up and select the larger of the mass and final current counts. The additional initial screen uses the same final geometry as a conservative check.