CorrosionRateLab
Menu

Initial polarization above installed supply

A structure has an unusually high commissioning current requirement. Mean and final breakdown remain low.

Inputs

SI units

Enter bare-metal design current density for each phase and its associated coating breakdown. Use final stand-off anode dimensions.

m²
yr
%
mA/m²
%
mA/m²
%
mA/m²
%
kg
m
m
V
Ω·m
Required mass
49.47 kg
Anodes needed
2
Output / anode
2.65 A
Capacity life
17.79 yr

Galvanic current field

Schematic
Galvanic current field (schematic, not to scale)Anode metalProtected steelConventional current through electrolyteDRIVING VOLTAGE0.25 VFINAL DEMAND3.84 AANODE OUTPUT2.65 A
Initial current shortfall

The modeled initial or final demand exceeds supply. Check the available driving potential and add capacity for initial polarization.

Current supply requires review

Calculation details

Alloy design capacity
2,000 A·h/kg
Initial demand
117 A
Mean demand
1.2 A
Final demand
3.84 A
Final single-anode resistance
0.0942 Ω
Count by net mass
1
Count by final current
2
Count for initial polarization
45
Installed net mass
110 kg
Total installed current output
5.31 A

Worked calculation

Starting values · SI
  1. Initial, mean and final current demands are 117, 1.2 and 3.84 A.
  2. Mean demand and 2,000 A·h/kg capacity give 49.46824 kg required alloy mass.
  3. Final resistance is 0.0942 Ω with 2.65402 A per anode. Count by mass is 1, by final current 2 and by initial current 45.

The mass and final current count is still calculated. The separate initial check flags a shortfall and reports the initial count.

Method and limits

  1. Estimate demand at three stages

    For each stage, demand = protected area × coating breakdown × corresponding bare current density. Convert percent to a fraction and mA/m² to A/m².

  2. Calculate net alloy mass

    M = mean demand × 8,760 × design years ÷ (capacity × utilization). Divide by net mass per anode and round up. Preset capacities are 2,000, 780 and 1,100 A·h/kg for aluminum, zinc and magnesium, respectively.

  3. Check final and initial current

    For a slender stand-off anode, R = ρ[ln(4L/r) − 1]/(2πL), with L ≥ 4r. Current per anode is ΔE/R. Round final demand divided by single-anode current up and select the larger of the mass and final current counts. The additional initial screen uses the same final geometry as a conservative check.