Modified B31G at z = 50
A 500 mm OD pipe with 10 mm wall thickness has a 500 mm axial corrosion length and 3 mm depth.
Inputs
SI unitsEnter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.
- Burst pressure
- 13,439.2 kPa
- Safe pressure
- 9,676.22 kPa
- ERF
- 0.672
- Wall loss
- 30 %
Axial metal-loss profile
SchematicThe entered MAOP fits the selected pressure screen. Verify the defect profile, interactions, safety factor and jurisdiction before disposition.
Calculation details
- Length parameter z
- 50
- Original Folias M
- —
- Modified Folias M
- 4.893
- Selected pressure result
- Modified B31G
- Original flow stress
- 394.38 MPa
- Modified flow stress
- 427.47 MPa
- Original predicted failure
- 11,042.64 kPa
- Modified predicted failure
- 13,439.2 kPa
- Original safe pressure
- 7,950.7 kPa
- Modified safe pressure
- 9,676.22 kPa
- Intact-wall design cap
- 10,325.59 kPa
- Screened pressure minus MAOP
- 3,176.22 kPa
Inputs used
- Governing method
- Modified B31G
- Outside diameter
- 500 mm
- Sound wall thickness
- 10 mm
- Pipe grade SMYS
- 358.52738 MPa
- Design factor F
- 0.72
- Operating MAOP
- 6,500 kPa
- Metal-loss depth
- 3 mm
- Axial defect length
- 500 mm
Worked calculation
Starting values · SI- Depth ratio is 30%. The length parameter z is 50.
- Original and Modified failure estimates are 11,042.64328 and 13,439.19877 kPa, respectively.
- With F = 0.72, the selected safe pressure is 9,676.22312 kPa and ERF is 0.67175.
The polynomial Folias factor applies at equality. Increase length slightly to see the modified linear branch.
Method and limits
Calculate the loss and length ratios
Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.
Evaluate the two profiles
Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.
Screen the pressure
For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.