Selected rectifier tap too low

An existing rectifier has a 36 V tap. The project wants to keep the design factor of 1.25 at the measured conditions.

Inputs

SI units

Use complete loop cable resistance and an independent estimate of back-EMF. Enter a manufacturer tap to override the example tap list.

A
Ω
Ω
Ω
V
×
V Blank selects the next listed tap.
%
USD/kWh
hr/yr
Required DC
32.85 V
Rated tap
36 V
AC load
1.33 kVA
Annual energy
10,833.54 kWh/yr

Transformer-rectifier circuit

Schematic
Transformer-rectifier circuit (schematic, not to scale)AC supplyRectifierDC loopTransformer / rectifierOPERATING DC32.85 VDESIGN MINIMUM41.06 VSELECTED TAP36 V
Selected tap is too low

Select a manufacturer rating that meets the design voltage and DC current under site conditions.

Design voltage exceeds available tap

Calculation details

Total loop resistance
1 Ω
Minimum design voltage
41.06 V
Operating DC power
1.051 kW
Operating AC real power
1.237 kW
Operating AC apparent power
1.33 kVA
DC load at tap and design current
1.152 kW
AC input at tap and design current
1.457 kVA
Tap headroom over operating voltage
9.59 %
Tap minus design voltage
-5.06 V
Annual operating electricity
1,516.7 USD/yr

Worked calculation

Starting values · SI
  1. Loop resistance is 1 Ω. Required voltage is 32.85 V before the 1.25× design multiplier.
  2. The design minimum is 41.0625 V and the selected tap is 36 V.
  3. Operating load is 1.23671 kW and 1.32979 kVA. Over 8,760 hours, energy is 10,833.54353 kWh/yr.

A selected tap can exceed operating voltage while failing the required design margin. Compare both values.

Method and limits

  1. Build the DC voltage budget

    Required voltage = current × (groundbed + structure + loop cable resistance) + opposing back-EMF. Multiply by the design factor for the minimum design voltage.

  2. Check the tap and AC supply

    Use the first listed tap at or above the design voltage, or enter a nameplate tap. DC kW = operating voltage × current ÷ 1,000. AC kW = DC kW ÷ efficiency. AC kVA = AC kW ÷ power factor. Rated load at the selected tap is shown separately.

  3. Estimate running cost

    AC kW × annual runtime gives kWh/yr. Multiply by the entered tariff for annual cost. Headroom is (tap − operating voltage) ÷ operating voltage.