Zero entered protection load
A disconnected test circuit is entered with zero protection current and zero back-EMF.
Inputs
SI unitsUse complete loop cable resistance and an independent estimate of back-EMF. Enter a manufacturer tap to override the example tap list.
- Required DC
- 0 V
- Rated tap
- —
- AC load
- 0 kVA
- Annual energy
- 0 kWh/yr
Transformer-rectifier circuit
SchematicConfirm the input current and loop voltage. Annual energy excludes idle and standby losses.
Calculation details
- Total loop resistance
- 1 Ω
- Minimum design voltage
- 0 V
- Operating DC power
- 0 kW
- Operating AC real power
- 0 kW
- Operating AC apparent power
- 0 kVA
- DC load at tap and design current
- —
- AC input at tap and design current
- —
- Tap headroom over operating voltage
- —
- Tap minus design voltage
- —
- Annual operating electricity
- 0 USD/yr
Inputs used
- Protection current
- 0 A
- Groundbed
- 0.65 Ω
- Structure resistance
- 0.2 Ω
- Loop cable
- 0.15 Ω
- Back-EMF
- 0 V
- Design multiplier
- 1.25 ×
- Selected DC tap
- —
- Rectifier efficiency
- 85 %
- Power factor
- 0.93
- Electricity tariff
- 0.14 USD/kWh
- Annual runtime
- 8,760 hr/yr
Worked calculation
Starting values · SI- Loop resistance is 1 Ω. Required voltage is 0 V before the 1.25× design multiplier.
- The design minimum is 0 V and the selected tap is unavailable or unused.
- Operating load is 0 kW and 0 kVA. Over 8,760 hours, energy is 0 kWh/yr.
The idealized load and energy are zero, while a real transformer-rectifier can draw power at idle.
Method and limits
Build the DC voltage budget
Required voltage = current × (groundbed + structure + loop cable resistance) + opposing back-EMF. Multiply by the design factor for the minimum design voltage.
Check the tap and AC supply
Use the first listed tap at or above the design voltage, or enter a nameplate tap. DC kW = operating voltage × current ÷ 1,000. AC kW = DC kW ÷ efficiency. AC kVA = AC kW ÷ power factor. Rated load at the selected tap is shown separately.
Estimate running cost
AC kW × annual runtime gives kWh/yr. Multiply by the entered tariff for annual cost. Headroom is (tap − operating voltage) ÷ operating voltage.