Voltage above the candidate tap list
A modeled high-resistance circuit calls for 190 A and 5.6 Ω total loop resistance.
Inputs
SI unitsUse complete loop cable resistance and an independent estimate of back-EMF. Enter a manufacturer tap to override the example tap list.
- Required DC
- 1,064.85 V
- Rated tap
- —
- AC load
- 255.941 kVA
- Annual energy
- 2,085,101.58 kWh/yr
Transformer-rectifier circuit
SchematicSelect a manufacturer rating that meets the design voltage and DC current under site conditions.
Calculation details
- Total loop resistance
- 5.6 Ω
- Minimum design voltage
- 1,331.06 V
- Operating DC power
- 202.321 kW
- Operating AC real power
- 238.025 kW
- Operating AC apparent power
- 255.941 kVA
- DC load at tap and design current
- —
- AC input at tap and design current
- —
- Tap headroom over operating voltage
- —
- Tap minus design voltage
- —
- Annual operating electricity
- 291,914.22 USD/yr
Inputs used
- Protection current
- 190 A
- Groundbed
- 5 Ω
- Structure resistance
- 0.4 Ω
- Loop cable
- 0.2 Ω
- Back-EMF
- 0.85 V
- Design multiplier
- 1.25 ×
- Selected DC tap
- —
- Rectifier efficiency
- 85 %
- Power factor
- 0.93
- Electricity tariff
- 0.14 USD/kWh
- Annual runtime
- 8,760 hr/yr
Worked calculation
Starting values · SI- Loop resistance is 5.6 Ω. Required voltage is 1,064.85 V before the 1.25× design multiplier.
- The design minimum is 1,331.0625 V and the selected tap is unavailable or unused.
- Operating load is 238.02529 kW and 255.94118 kVA. Over 8,760 hours, energy is 2,085,101.57647 kWh/yr.
No candidate tap meets the design voltage. Check the resistance assumption and obtain purpose-built equipment data where appropriate.
Method and limits
Build the DC voltage budget
Required voltage = current × (groundbed + structure + loop cable resistance) + opposing back-EMF. Multiply by the design factor for the minimum design voltage.
Check the tap and AC supply
Use the first listed tap at or above the design voltage, or enter a nameplate tap. DC kW = operating voltage × current ÷ 1,000. AC kW = DC kW ÷ efficiency. AC kVA = AC kW ÷ power factor. Rated load at the selected tap is shown separately.
Estimate running cost
AC kW × annual runtime gives kWh/yr. Multiply by the entered tariff for annual cost. Headroom is (tap − operating voltage) ÷ operating voltage.