API 520 I · API 526
High-backpressure vapor PSV
A fixed superimposed pressure and small built-up rise leave a conventional valve in the subcritical regime.
Use the displayed F₂ for the flow-capacity calculation. Verify how the superimposed pressure is compensated at opening.
Operating readout
Edit inputs ↓- API 526 letter
- K
- Required area
- 1,182.222mm²
- Relief reserve
- 0.3%
- Nozzle regime
- Subcritical
Calculated details
- Selected effective area
- 1,185.804mm²
- Screened capacity (largest if beyond T)
- 7,021.21kg/h
- Flowing inlet pressure P₁
- 728.33kPa(a)
- Total outlet backpressure P₂
- 535kPa(a)
- Critical flow pressure Pcf
- 422.8kPa(a)
- Subcritical coefficient F₂
- 0.81178
- Nozzle C (SI)
- 0.024972
- Nozzle C (US)
- 328.91
- Applied Kb
- 1
- Effective area method
- Subcritical F₂
Operating inputs
Operating inputs
- Gauge set pressure
- 5.7bar(g)
- Allowable overpressure
- 10%
- Atmospheric pressure
- 101.325kPa(a)
- Superimposed backpressure
- 500kPa(a)
- Built-up backpressure
- 35kPa
- Required relief flow W
- 7,000kg/h
- Relieving temperature
- 74°C
- Molecular weight
- 42kg/kmol
- Relieving compressibility Z
- 0.95
- Ideal-gas heat ratio k
- 1.12
- Discharge coefficient Kd
- 0.975
- Valve type
- Conventional
- Rupture-disk factor Kc
- 1
Calculated details
- Selected effective area
- 1,185.804mm²
- Screened capacity (largest if beyond T)
- 7,021.21kg/h
- Flowing inlet pressure P₁
- 728.33kPa(a)
- Total outlet backpressure P₂
- 535kPa(a)
- Critical flow pressure Pcf
- 422.8kPa(a)
- Subcritical coefficient F₂
- 0.81178
- Nozzle C (SI)
- 0.024972
- Nozzle C (US)
- 328.91
- Applied Kb
- 1
- Effective area method
- Subcritical F₂
Gas and vapor only. Use the correct relieving load, accumulation, combination factor and manufacturer capacity data for the actual service. Check certified capacity, built-up and superimposed backpressure, valve lift, inlet pressure loss, and two-phase or near-critical behavior separately.
Calculation basis
Set the relieving pressures
P₁ = P_set,g(1 + overpressure) + P_atm. P₂ adds built-up pressure to the superimposed absolute pressure. The ideal-gas critical boundary is Pcf = P₁[2/(k + 1)]^(k/(k − 1)).
Apply the correct capacity equation
Critical area uses C = 0.03948√[k(2/(k + 1))^((k + 1)/(k − 1))] in SI (520 in US). Conventional subcritical area uses the exact F₂ and SI coefficient 17.9, with a critical-area floor to cover coefficient rounding. Balanced valves use a manufacturer Kb that accounts for subcritical flow and stays within the full-lift nozzle capacity.
Select effective area
Select the smallest API 526 letter with effective area at or above the calculated area. Reserve is selected area divided by required area minus one.
Related worked examples
-
Methane blocked-outlet PSV →
An outlet isolation scenario sends 8.4 t/h of methane vapor to a low-backpressure relief header.
-
Balanced bellows into a flare header →
A balanced bellows PSV handles a volatile vapor at an outlet pressure above its critical boundary.
-
Upstream rupture disk combination →
A vapor relief valve has an upstream disk with a preliminary combination factor of 0.90.
-
Small nitrogen isolation relief →
An isolated nitrogen utility section needs 230 kg/h gas relief at a modest set pressure.
-
Vapor duty beyond API 526 T →
A deliberately large 310 t/h vapor load exceeds the largest single standardized orifice in the screen.
-
Relief sizing at a high-altitude plant →
A vessel at a high-altitude plant uses 82 kPa local atmosphere for gauge-to-absolute conversion.