Mixed-gas office triple glazing

An office retrofit uses a wider air cavity outside and a narrower argon cavity inside.

Center-of-glass thermal model

Inputs

Glazing build-up
mm
mm
mm
m
m
Exterior cavity
mm
Interior cavity
mm
Climate and solar data
°C
°C
%

Screening result

The center of glass is at least 2 K above the indoor dew point.

Pass
Glass U-factor
0.894W/(m²·K)
Glass SHGC
0.491
Glass surface
18.5°C
Dew margin
8.39K
Insulating glass section and temperature profileIGU heat and condensation. Glass U-factor 0.894 W/(m²·K). Glass SHGC 0.491. Glass surface 18.5 °C. Dew margin 8.39 K.Insulating glass section3 panes · sealed vertical cavitiesExteriorInteriorTemperature profileOutdoor to room side-16 °C23 °CGlass profileDew 10.1 °CCenter-glass dew margin−5 KDew point+5 K

Calculation details

Indoor dew point
10.086 °C
Glass plus linear edge U-factor
0.991 W/(m²·K)
Linear spacer transmittance Ψ
0.04 W/(m·K)
Heat flux toward exterior
34.85 W/m²
Cavity 1 gas conductance
2.004 W/(m²·K)
Cavity 1 radiative conductance
0.5 W/(m²·K)
Cavity 2 gas conductance
1.571 W/(m²·K)
Cavity 2 radiative conductance
0.302 W/(m²·K)

Formula trace in SI

  1. Gas and radiation

    hgap = Nu·k/d + σεeff(T₁ + T₂)(T₁² + T₂²)

    Gap 1: 0.979 conductive × Nu 2.047 + 0.5 radiative W/(m²·K). Gap 2: 1.528 conductive × Nu 1.028 + 0.302 radiative W/(m²·K).

  2. Center and edge heat flow

    Uc = 1/ΣR; Uglass+edge = Uc + ΨP/A

    ΣR = 1.119 m²·K/W, edge addition 0.097 W/(m²·K).

  3. Solar gain

    SHGC = τsolar + αsolar·Rout/Rtotal

    Inward absorbed fraction 3.84 %, SHGC 0.491.

  4. Condensation margin

    Tsi = Ti − q/hin; ΔTdew = Tsi − Tdp

    Magnus dew point 10.086 °C, surface 18.474 °C, margin 8.388 K.