12,000 BTU Mini-Split for a One-Car Garage
Check a 12,000 BTU mini-split against a 450 ft² garage with three exterior walls, winter leakage and an insulated ceiling.
Inputs
Results ↓Results
Example estimate- Walls and ceiling · 1,150 cool / 3,720 heat
- Exposed floor · 0 cool / 0 heat
- Windows and sun · 1,253 cool / 731 heat
- Outdoor air leakage · 2,016 cool / 4,440 heat
- People and equipment · 790 cool / 0 heat
- Modeled cooling load
- 5,208.4 BTU/h
- Modeled heating loss
- 8,890.9 BTU/h
- Cooling load in tons
- 0.43 tons
- Minimum nominal capacity
- 9,655.3 BTU/h
- Cold-weather capacity
- 92.1 % of nominal
- Heating output at design
- 11,050 BTU/h
- Summer / winter design
- 90°F / 12°F
- Modeled outdoor leakage
- 70.9 CFM
- The capacity curve is illustrative. Verify delivered heating capacity and operating limits for the exact model.
Calculation inputs
- Floor area
- 450 ft²
- Ceiling height
- 9 ft
- People in the room
- 1
- Room type
- Standard room
- Size for
- Heating and cooling
- Wall perimeter facing outdoors
- 75 %
- Effective wall R-value
- 12
- Effective ceiling R-value
- 24
- Effective exposed floor R-value
- 0
- Exterior window area
- 28 ft²
- Window U-factor
- 0.45
- Main window exposure
- East
- Estimated outdoor air leakage
- 1.05 ACH
- Illustrative climate zone
- 4 · Mixed
- Design temperature source
- Climate zone example
- Low-temperature capacity
- Cold-climate inverter curve
Worked example
This one-car shop shares one wall with the house. The 9 ft ceiling and three exterior walls contribute to design loss, but the overhead door’s air leakage is the deciding input. Try reducing leakage from 1.05 to 0.6 ACH after a weather-seal upgrade.
Suggested nominal class 12,000 BTU/h
What to check next
Record indoor temperature one hour after the overhead door shuts on a cold day. Use a local design temperature and look up capacity for the intended garage setpoint before buying.
Formulas and assumptions
- Envelope load
- BTU/h = Σ(area × ΔT ÷ effective R) + window area × U × ΔT. Exposed ceilings add a 10°F summer solar allowance.
- Air and internal gains
- Leakage CFM = room volume × ACH ÷ 60. Sensible airflow load uses 1.08 × CFM × ΔT. Cooling also includes 0.68 × CFM × the zone moisture difference in grains, window solar gain, people and equipment.
- Capacity and tons
- Cooling tons = cooling BTU/h ÷ 12,000. For heating, divide design heat loss by the capacity ratio. Size up to the first listed nominal class that meets the selected load.
Frequently asked questions
Will a 12k mini-split recover after a one-car garage door opens?
The estimate describes a closed garage at design conditions. Door-opening recovery is a separate transient load that depends on duration and wind.
Which garage insulation should I use when the door has a lower R-value?
Use an effective exterior wall R-value that accounts for the door or calculate the door separately when it occupies much of the exterior wall.