12,000 BTU Mini-Split for a One-Car Garage

Check a 12,000 BTU mini-split against a 450 ft² garage with three exterior walls, winter leakage and an insulated ceiling.

Room and use
Envelope and glazing

50% is two sides of a square room.

Use 0 if a conditioned space is above.

Use 0 to omit floor loss. Slab edges need separate modeling.

Use the whole-window rating in Btu/(h·ft²·°F).

Use natural air changes, not ACH50 from a blower-door test.

Weather and equipment

Sets example weather. Use local design temperatures when available.

Results

Example estimate
Suggested nominal class12,000 BTU/h
Cooling5,208 BTU/h 1,149.7 BTU/h0 BTU/h1,253 BTU/h2,015.7 BTU/h790 BTU/hHeating8,891 BTU/h 3,720.5 BTU/h0 BTU/h730.8 BTU/h4,439.6 BTU/h0 BTU/h
Each bar uses the same BTU/h scale.
  • Walls and ceiling · 1,150 cool / 3,720 heat
  • Exposed floor · 0 cool / 0 heat
  • Windows and sun · 1,253 cool / 731 heat
  • Outdoor air leakage · 2,016 cool / 4,440 heat
  • People and equipment · 790 cool / 0 heat
Modeled cooling load
5,208.4 BTU/h
Modeled heating loss
8,890.9 BTU/h
Cooling load in tons
0.43 tons
Minimum nominal capacity
9,655.3 BTU/h
Cold-weather capacity
92.1 % of nominal
Heating output at design
11,050 BTU/h
Summer / winter design
90°F / 12°F
Modeled outdoor leakage
70.9 CFM
  • The capacity curve is illustrative. Verify delivered heating capacity and operating limits for the exact model.

Worked example

This one-car shop shares one wall with the house. The 9 ft ceiling and three exterior walls contribute to design loss, but the overhead door’s air leakage is the deciding input. Try reducing leakage from 1.05 to 0.6 ACH after a weather-seal upgrade.

Suggested nominal class 12,000 BTU/h

What to check next

Record indoor temperature one hour after the overhead door shuts on a cold day. Use a local design temperature and look up capacity for the intended garage setpoint before buying.

Formulas and assumptions

Envelope load
BTU/h = Σ(area × ΔT ÷ effective R) + window area × U × ΔT. Exposed ceilings add a 10°F summer solar allowance.
Air and internal gains
Leakage CFM = room volume × ACH ÷ 60. Sensible airflow load uses 1.08 × CFM × ΔT. Cooling also includes 0.68 × CFM × the zone moisture difference in grains, window solar gain, people and equipment.
Capacity and tons
Cooling tons = cooling BTU/h ÷ 12,000. For heating, divide design heat loss by the capacity ratio. Size up to the first listed nominal class that meets the selected load.

Frequently asked questions

Will a 12k mini-split recover after a one-car garage door opens?

The estimate describes a closed garage at design conditions. Door-opening recovery is a separate transient load that depends on duration and wind.

Which garage insulation should I use when the door has a lower R-value?

Use an effective exterior wall R-value that accounts for the door or calculate the door separately when it occupies much of the exterior wall.

More sizing examples

Open the general mini-split sizing calculator