18,000 BTU Mini-Split for a Loft Bedroom

Estimate an 18,000 BTU class for a 650 ft² loft bedroom with 12 ft ceilings and a large bank of west-facing windows.

Room and use
Envelope and glazing

50% is two sides of a square room.

Use 0 if a conditioned space is above.

Use 0 to omit floor loss. Slab edges need separate modeling.

Use the whole-window rating in Btu/(h·ft²·°F).

Use natural air changes, not ACH50 from a blower-door test.

Weather and equipment

Sets example weather. Use local design temperatures when available.

Results

Example estimate
Suggested nominal class18,000 BTU/h
Cooling17,457 BTU/h 1,384.9 BTU/h0 BTU/h11,987.3 BTU/h2,705 BTU/h1,380 BTU/hHeating9,997 BTU/h 3,023.6 BTU/h0 BTU/h3,267 BTU/h3,706.6 BTU/h0 BTU/h
Each bar uses the same BTU/h scale.
  • Walls and ceiling · 1,385 cool / 3,024 heat
  • Exposed floor · 0 cool / 0 heat
  • Windows and sun · 11,987 cool / 3,267 heat
  • Outdoor air leakage · 2,705 cool / 3,707 heat
  • People and equipment · 1,380 cool / 0 heat
Modeled cooling load
17,457.2 BTU/h
Modeled heating loss
9,997.2 BTU/h
Cooling load in tons
1.45 tons
Minimum nominal capacity
17,457.2 BTU/h
Cold-weather capacity
96.5 % of nominal
Heating output at design
17,370 BTU/h
Summer / winter design
92°F / 26°F
Modeled outdoor leakage
78 CFM
  • The capacity curve is illustrative. Verify delivered heating capacity and operating limits for the exact model.

Worked example

A loft-sized conditioned zone includes the sleeping area and an open sitting area. A 12 ft ceiling adds volume and exposed wall area. This example uses the 18k class because of the glass and exposure together.

Suggested nominal class 18,000 BTU/h

What to check next

Check whether the loft is open to air from another level. Measure the whole connected conditioned zone before assuming a single head can serve it.

Formulas and assumptions

Envelope load
BTU/h = Σ(area × ΔT ÷ effective R) + window area × U × ΔT. Exposed ceilings add a 10°F summer solar allowance.
Air and internal gains
Leakage CFM = room volume × ACH ÷ 60. Sensible airflow load uses 1.08 × CFM × ΔT. Cooling also includes 0.68 × CFM × the zone moisture difference in grains, window solar gain, people and equipment.
Capacity and tons
Cooling tons = cooling BTU/h ÷ 12,000. For heating, divide design heat loss by the capacity ratio. Size up to the first listed nominal class that meets the selected load.

Frequently asked questions

Can a bedroom loft use a 1.5-ton mini-split without short cycling?

Compare the actual load range with the model’s compressor turndown. The peak scenario alone gives little information about mild weather or overnight operation.

Does vaulted loft geometry change the mini-split room estimate?

Use average ceiling height for volume and check sloped roof and wall areas separately for a precise calculation. Large irregular lofts benefit from a detailed load model.

More sizing examples

Open the general mini-split sizing calculator