18,000 BTU Mini-Split for a Loft Bedroom
Estimate an 18,000 BTU class for a 650 ft² loft bedroom with 12 ft ceilings and a large bank of west-facing windows.
Inputs
Results ↓Results
Example estimate- Walls and ceiling · 1,385 cool / 3,024 heat
- Exposed floor · 0 cool / 0 heat
- Windows and sun · 11,987 cool / 3,267 heat
- Outdoor air leakage · 2,705 cool / 3,707 heat
- People and equipment · 1,380 cool / 0 heat
- Modeled cooling load
- 17,457.2 BTU/h
- Modeled heating loss
- 9,997.2 BTU/h
- Cooling load in tons
- 1.45 tons
- Minimum nominal capacity
- 17,457.2 BTU/h
- Cold-weather capacity
- 96.5 % of nominal
- Heating output at design
- 17,370 BTU/h
- Summer / winter design
- 92°F / 26°F
- Modeled outdoor leakage
- 78 CFM
- The capacity curve is illustrative. Verify delivered heating capacity and operating limits for the exact model.
Calculation inputs
- Floor area
- 650 ft²
- Ceiling height
- 12 ft
- People in the room
- 2
- Room type
- Standard room
- Size for
- Heating and cooling
- Wall perimeter facing outdoors
- 75 %
- Effective wall R-value
- 16
- Effective ceiling R-value
- 30
- Effective exposed floor R-value
- 0
- Exterior window area
- 165 ft²
- Window U-factor
- 0.45
- Main window exposure
- West
- Estimated outdoor air leakage
- 0.6 ACH
- Illustrative climate zone
- 3 · Warm
- Design temperature source
- Climate zone example
- Low-temperature capacity
- Cold-climate inverter curve
Worked example
A loft-sized conditioned zone includes the sleeping area and an open sitting area. A 12 ft ceiling adds volume and exposed wall area. This example uses the 18k class because of the glass and exposure together.
Suggested nominal class 18,000 BTU/h
What to check next
Check whether the loft is open to air from another level. Measure the whole connected conditioned zone before assuming a single head can serve it.
Formulas and assumptions
- Envelope load
- BTU/h = Σ(area × ΔT ÷ effective R) + window area × U × ΔT. Exposed ceilings add a 10°F summer solar allowance.
- Air and internal gains
- Leakage CFM = room volume × ACH ÷ 60. Sensible airflow load uses 1.08 × CFM × ΔT. Cooling also includes 0.68 × CFM × the zone moisture difference in grains, window solar gain, people and equipment.
- Capacity and tons
- Cooling tons = cooling BTU/h ÷ 12,000. For heating, divide design heat loss by the capacity ratio. Size up to the first listed nominal class that meets the selected load.
Frequently asked questions
Can a bedroom loft use a 1.5-ton mini-split without short cycling?
Compare the actual load range with the model’s compressor turndown. The peak scenario alone gives little information about mild weather or overnight operation.
Does vaulted loft geometry change the mini-split room estimate?
Use average ceiling height for volume and check sloped roof and wall areas separately for a precise calculation. Large irregular lofts benefit from a detailed load model.