18,000 BTU Mini-Split for a Two-Car Garage
Run an 18,000 BTU sizing example for a 650 ft² detached garage with four exposed walls, two occupants and west-facing windows.
Inputs
Results ↓Results
Example estimate- Walls and ceiling · 1,983 cool / 6,664 heat
- Exposed floor · 0 cool / 0 heat
- Windows and sun · 3,014 cool / 1,096 heat
- Outdoor air leakage · 2,619 cool / 5,768 heat
- People and equipment · 1,380 cool / 0 heat
- Modeled cooling load
- 8,995.7 BTU/h
- Modeled heating loss
- 13,528 BTU/h
- Cooling load in tons
- 0.75 tons
- Minimum nominal capacity
- 14,691 BTU/h
- Cold-weather capacity
- 92.1 % of nominal
- Heating output at design
- 16,575 BTU/h
- Summer / winter design
- 90°F / 12°F
- Modeled outdoor leakage
- 92.1 CFM
- The capacity curve is illustrative. Verify delivered heating capacity and operating limits for the exact model.
Calculation inputs
- Floor area
- 650 ft²
- Ceiling height
- 10 ft
- People in the room
- 2
- Room type
- Standard room
- Size for
- Heating and cooling
- Wall perimeter facing outdoors
- 100 %
- Effective wall R-value
- 11
- Effective ceiling R-value
- 25
- Effective exposed floor R-value
- 0
- Exterior window area
- 42 ft²
- Window U-factor
- 0.45
- Main window exposure
- West
- Estimated outdoor air leakage
- 0.85 ACH
- Illustrative climate zone
- 4 · Mixed
- Design temperature source
- Climate zone example
- Low-temperature capacity
- Cold-climate inverter curve
Worked example
The detached two-car example loses heat through all four walls and the roof. The heating requirement drives the nominal class after derating at 12°F. Select Cooling only to see the class for summer workshop use.
Suggested nominal class 18,000 BTU/h
What to check next
Check the minimum modulation of an 18k candidate on mild days as well as its maximum heat at the outdoor design point. Tools and vehicles can change actual gains during the day.
Formulas and assumptions
- Envelope load
- BTU/h = Σ(area × ΔT ÷ effective R) + window area × U × ΔT. Exposed ceilings add a 10°F summer solar allowance.
- Air and internal gains
- Leakage CFM = room volume × ACH ÷ 60. Sensible airflow load uses 1.08 × CFM × ΔT. Cooling also includes 0.68 × CFM × the zone moisture difference in grains, window solar gain, people and equipment.
- Capacity and tons
- Cooling tons = cooling BTU/h ÷ 12,000. For heating, divide design heat loss by the capacity ratio. Size up to the first listed nominal class that meets the selected load.
Frequently asked questions
Is an 18k unit a good match for a detached 650 ft² shop?
It depends on winter heat loss and the unit’s low-temperature capacity. Confirm those two numbers and compare the unit’s turndown at light loads.
How do I model a two-car garage that shares a long wall with the home?
Set the percentage of the perimeter exposed to outdoors. A shared conditioned boundary reduces the exterior wall area used for transmission.