24,000 BTU Mini-Split for a Large Bedroom Suite
Explore a 24,000 BTU cooling example for a 900 ft² primary suite with a high ceiling and expansive west glazing.
Inputs
Results ↓Results
Example estimate- Walls and ceiling · 1,951 cool / 8,023 heat
- Exposed floor · 0 cool / 0 heat
- Windows and sun · 15,686 cool / 6,930 heat
- Outdoor air leakage · 3,667 cool / 11,907 heat
- People and equipment · 1,580 cool / 0 heat
- Modeled cooling load
- 22,883.4 BTU/h
- Modeled heating loss
- 26,860.1 BTU/h
- Cooling load in tons
- 1.91 tons
- Minimum nominal capacity
- 22,883.4 BTU/h
- Cold-weather capacity
- 83.6 % of nominal
- Heating output at design
- 20,053.3 BTU/h
- Summer / winter design
- 89°F / 0°F
- Modeled outdoor leakage
- 157.5 CFM
Calculation inputs
- Floor area
- 900 ft²
- Ceiling height
- 14 ft
- People in the room
- 2
- Room type
- Standard room
- Size for
- Cooling only
- Wall perimeter facing outdoors
- 75 %
- Effective wall R-value
- 13
- Effective ceiling R-value
- 26
- Effective exposed floor R-value
- 0
- Exterior window area
- 220 ft²
- Window U-factor
- 0.45
- Main window exposure
- West
- Estimated outdoor air leakage
- 0.75 ACH
- Illustrative climate zone
- 5 · Cool
- Design temperature source
- Climate zone example
- Low-temperature capacity
- Cold-climate inverter curve
Worked example
This example treats an unusual 900 ft² suite as one open zone, with 14 ft height and 220 ft² of west glazing. The cooling class can land at 24k even though ordinary bedrooms have much smaller loads.
Suggested nominal class 24,000 BTU/h
What to check next
Switch to Heating and cooling to see the higher requirement at the model’s 0°F winter design temperature. Doors between the bedroom, closet and bath can prevent one head from serving the entire suite.
Formulas and assumptions
- Envelope load
- BTU/h = Σ(area × ΔT ÷ effective R) + window area × U × ΔT. Exposed ceilings add a 10°F summer solar allowance.
- Air and internal gains
- Leakage CFM = room volume × ACH ÷ 60. Sensible airflow load uses 1.08 × CFM × ΔT. Cooling also includes 0.68 × CFM × the zone moisture difference in grains, window solar gain, people and equipment.
- Capacity and tons
- Cooling tons = cooling BTU/h ÷ 12,000. For heating, divide design heat loss by the capacity ratio. Size up to the first listed nominal class that meets the selected load.
Frequently asked questions
What bedroom layout makes a 24k wall head worth comparing?
A large connected suite with high ceilings and extensive unshaded glass may have enough peak load. Check individual room loads and air paths before choosing a single head.
Should the suite cooling class also determine winter heating size?
Compare both loads independently. At the design temperature, a combined heating-and-cooling choice may need a higher nominal class or backup heat.