24,000 BTU Mini-Split for a Large Bedroom Suite

Explore a 24,000 BTU cooling example for a 900 ft² primary suite with a high ceiling and expansive west glazing.

Room and use
Envelope and glazing

50% is two sides of a square room.

Use 0 if a conditioned space is above.

Use 0 to omit floor loss. Slab edges need separate modeling.

Use the whole-window rating in Btu/(h·ft²·°F).

Use natural air changes, not ACH50 from a blower-door test.

Weather and equipment

Sets example weather. Use local design temperatures when available.

Results

Example estimate
Suggested nominal class24,000 BTU/h
Cooling22,883 BTU/h 1,950.8 BTU/h0 BTU/h15,686 BTU/h3,666.6 BTU/h1,580 BTU/hHeating26,860 BTU/h 8,023.1 BTU/h0 BTU/h6,930 BTU/h11,907 BTU/h0 BTU/h
Each bar uses the same BTU/h scale.
  • Walls and ceiling · 1,951 cool / 8,023 heat
  • Exposed floor · 0 cool / 0 heat
  • Windows and sun · 15,686 cool / 6,930 heat
  • Outdoor air leakage · 3,667 cool / 11,907 heat
  • People and equipment · 1,580 cool / 0 heat
Modeled cooling load
22,883.4 BTU/h
Modeled heating loss
26,860.1 BTU/h
Cooling load in tons
1.91 tons
Minimum nominal capacity
22,883.4 BTU/h
Cold-weather capacity
83.6 % of nominal
Heating output at design
20,053.3 BTU/h
Summer / winter design
89°F / 0°F
Modeled outdoor leakage
157.5 CFM

Worked example

This example treats an unusual 900 ft² suite as one open zone, with 14 ft height and 220 ft² of west glazing. The cooling class can land at 24k even though ordinary bedrooms have much smaller loads.

Suggested nominal class 24,000 BTU/h

What to check next

Switch to Heating and cooling to see the higher requirement at the model’s 0°F winter design temperature. Doors between the bedroom, closet and bath can prevent one head from serving the entire suite.

Formulas and assumptions

Envelope load
BTU/h = Σ(area × ΔT ÷ effective R) + window area × U × ΔT. Exposed ceilings add a 10°F summer solar allowance.
Air and internal gains
Leakage CFM = room volume × ACH ÷ 60. Sensible airflow load uses 1.08 × CFM × ΔT. Cooling also includes 0.68 × CFM × the zone moisture difference in grains, window solar gain, people and equipment.
Capacity and tons
Cooling tons = cooling BTU/h ÷ 12,000. For heating, divide design heat loss by the capacity ratio. Size up to the first listed nominal class that meets the selected load.

Frequently asked questions

What bedroom layout makes a 24k wall head worth comparing?

A large connected suite with high ceilings and extensive unshaded glass may have enough peak load. Check individual room loads and air paths before choosing a single head.

Should the suite cooling class also determine winter heating size?

Compare both loads independently. At the design temperature, a combined heating-and-cooling choice may need a higher nominal class or backup heat.

More sizing examples

Open the general mini-split sizing calculator