Basement Dehumidifier Dew Point and Slab Condensation
Check whether a 58°F basement slab can condense moisture from 70°F air at 65% RH and compare a drier target.
Inputs
Results ↓Results
Example estimate- Stull wet-bulb
- 62 °F
- Entering humidity ratio
- 70.9 gr/lb
- Entering enthalpy
- 27.87 BTU/lb dry air
- Leaving enthalpy
- 25.28 BTU/lb dry air
- Condensation at surface
- Above dew point
- Surface margin above dew point
- 0.3 °F
- Sensible load
- 0 BTU/h
- Latent load
- 2,858 BTU/h
- Total airside load
- 2,858 BTU/h
- Sensible heat ratio
- 0
Calculation inputs
- Entering dry-bulb temperature
- 70 °F
- Entering relative humidity
- 65 %
- Cold surface temperature
- 58 °F
- Barometric pressure
- 101.325 kPa
- Leaving dry-bulb temperature
- 70 °F
- Leaving relative humidity
- 50 %
- Airflow at the entering condition
- 250 CFM
Worked example
The slab is cooler than the surrounding basement air. Compare its 58°F surface temperature with the modeled dew point and lower RH to see how much moisture margin changes.
Entering-air dew point 57.7 °F
What to check next
Measure near the slab and in cooler corners. Determine whether moisture comes from humid air, liquid water or vapor passing through the assembly before choosing a dehumidifier.
Formulas and assumptions
- Moist-air state
- A Magnus water-vapor approximation gives dew point. Humidity ratio = 0.621945 × vapor pressure ÷ (barometric pressure − vapor pressure).
- Enthalpy and wet-bulb
- Enthalpy = 0.24 × °F + humidity ratio × (1061 + 0.444 × °F), in BTU/lb dry air. Stull estimates wet-bulb from dry-bulb and RH near standard pressure.
- Airside heat transfer
- Dry-air mass flow = 60 × CFM ÷ entering specific volume. Total BTU/h = mass flow × change in enthalpy. Sensible and latent components retain the sign of the transfer.
Frequently asked questions
Why does a basement floor look wet when the room air feels only slightly humid?
A cool slab can be below the air’s dew point while the air feels comfortable. Temperature and RH near the slab are more informative than RH upstairs.
Does lowering basement air to 50% RH always prevent floor condensation?
Check the coldest surface against the new dew point. A lower surface temperature or wetter local air can still cause condensation.